My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 1:02:11 PM
Creation date
11/8/2018 10:22:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HAMMER\1630\PR0518624\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
%901 ..i <br /> Garrett Backus, Senior REHS <br /> San Joaquin County <br /> Environmental Health Department—CUPA -2- February 26, 2013 <br /> 2. The service request page for the install and retrofit permits are signed by Costco. The <br /> Application For Underground Storage Tank Installation Permit is signed by Costco and <br /> Barghausen. The Application For Underground Storage Tank Retrofit or Piping Repair Permit <br /> is also signed by Costco and Barghausen. The Service Request Page and Application must <br /> all be signed by Costco or Bargausen. (Preferably Costco). <br /> Response: As discussed, we have revised both Service Request forms to indicate that <br /> Barghausen Consulting Engineers, Inc., as the Service Requestor, is the billing address. <br /> 3. Site Map T-3 Section E part 54 & 60 lists Fiberglass Systems 3" over 2" FRP. Fiberglass <br /> Systems should be changed to Ameron Dualoy. <br /> Response: The callout on Sheet T-3 has been revised to indicate Ameron Dualoy. <br /> 4. Site Map T-4 part 33 should list hydrostatic sensor-dual POINT float, with 4" NPT male <br /> adapter(for hydrostatic tank monitor). <br /> Response: The part description has been revised to indicate that it is a dual point float. <br /> 5. Site Maps that list the mechanical flapper at 95%should be changed to 90%. <br /> Response: All mechanical flapper valve callouts have been revised to indicate installation at <br /> 90 percent for overfill prevention. <br /> 6. Submit a copy of the Lubrizol compatibility letter for Blueline. <br /> Response: Please see the enclosed Manufacturer's Affirmative Statement of Compatibility <br /> prepared by Blueline Technologies dated February 7, 2013. <br /> 7. Site Maps T-1 & T-2 list the drop tube with mechanical flapper to be installed at 95% overfill <br /> prevention. Change 95% to 90%. <br /> Response: All mechanical flapper valve callouts have been revised to indicate installation at <br /> 90 percent for overfill prevention. <br /> The following outline provides each of the January 22, 2013 comments in italics exactly as written, along <br /> with a narrative response describing how each comment was addressed: <br /> 1. Does Containment Solutions have written instructions for doing the sump modification? Do <br /> they have guidelines for testing the sump modification in order to verify that the interstitial <br /> space has communication? if not, how will the contractor do both of these things? The letter <br /> states that they will complete the sump modification in accordance with the manufacturer <br /> specifications. What are the specifications? It also stated that: The installation of the new <br /> sump top will be completed such that there will be continuous monitoring within the interstitial <br /> space between all sensors. The double wall sump has only one sensor for the interstitial <br /> space. How will the contractor demonstrate that the brine from the new sump addition has <br /> communication with the existing sump? Brine could be used to show this, if the sump has a <br /> brine fill port at the bottom. Please let me know if you have any questions. <br /> Response: We have enclosed the applicable installation instructions provided by <br /> Containment Solutions for the retrofit and installation of the double-wall tank sumps. It is our <br />