My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
244
>
2300 - Underground Storage Tank Program
>
PR0231137
>
INSTALL_1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2019 11:41:29 AM
Creation date
11/8/2018 10:22:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1998
RECORD_ID
PR0231137
PE
2361
FACILITY_ID
FA0001554
FACILITY_NAME
MIRACLE MILE MARKET
STREET_NUMBER
244
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13708014
CURRENT_STATUS
01
SITE_LOCATION
244 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HARDING\244\PR0231137\1998 INSTALL .PDF
QuestysFileName
1998 INSTALL
QuestysRecordDate
7/21/2016 4:27:36 PM
QuestysRecordID
3149333
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10 PIPING 13 ADDING "AUKS AT EXISTING SITES <br /> All internal piping must be at least 4 inches (10 cm) Additional Xerxes Century-Cast FRP Tanks can be in- <br /> from the bottom of the tank. The I.D. of the 550-1,000 stalled at existing locations if proper foundation support <br /> gallon (2.1-3.8 cu. meters)tank is 48 inches 121.9 cm). exists.The method of installation is the responsibility of <br /> The I.D. of the 6 foot (1.8 meters) diameter tanks of the owner. It is required, however,that one of the follow- <br /> 2,000-6,000 gallons(7.6-22.8 cu.meters)is 71.5 inches ing methods be used.The preferred method is to install °„ <br /> (181.6 cm). The I.D. of the 2,000-12,000 gallon (6.1-45 a new tank in a separate hole at least 3 feet (1 meter) `_v <br /> cu. meters) tank is 91.5 inches (232.4 cm) and the I.D. from the original hole. Caution must be exercised in <br /> of the 15,000-20,000 gallon (57-76 cu. meters) tank is keeping unusual surface loads off existing tanks. The <br /> 119.375 inches(303.2 cm). All tanks must be vented to natural barrier of undisturbed soil between tanks must <br /> atmospheric pressure. be maintained. <br /> If this method is not practical, additional tanks may be <br /> 11 SUMPS buried in the same installation hole. After emptying ex- <br /> istingg tanks to less than one-quarter capacity, remove <br /> If tank has a sump, extra care must be exercised not to the surface pad. Enlarge the excavation for the new <br /> rest the tank on the sump prior to installation. tank, leaving as much backfill as possible around exist- <br /> When installing a tank with a sump, the 12 inches (30 Ing tanks. It may be necessary to install shoring to make <br /> cm) of bottom bedding must have an 8 inch (17.5 cm) sure that existing tanks do not move and that sufficient <br /> deep x 24 inch (60 cm) diameter hole centered at the backfill remains.The new tank must be installed by fol- <br /> sump location. After setting the tank, the void must be lowing the procedures <br /> hand backfilled and tamped. in this guide. Remem- <br /> ber to leave inches <br /> 12 FILLING THE TANK mum m 24 inches =u <br /> (60 cm) between <br /> The tank may be filled with water or product after the tanks. The backfill <br /> backfill is even with the top of the tank. Only under wet material must be the <br /> hole conditions as described in Item 8, should water or same as that speci- —� f-3' <br /> product be added before the backfill is even with the top fied in Item 3. <br /> of the tank. Also, when filling the tank with water or oI <br /> product, make sure the tank is adequately vented. <br /> CAUTION:The ballast level in the tank must not ex- till I I I, '�o <br /> ceed the water level in the hole during the ballast It 11 1 = <br /> procedure when sinking tank in a wet hole. <br /> WARRANTY <br /> Xerxes Corporation warrants that our underground storage tanks,if used in accordance with our specifications and installed according <br /> to our published installation instructions: <br /> (1)Will not fail for a period of thirty(30)years from date of original purchase due to external corrosion. <br /> (2)Will not fail for a period of thirty(30)years from date of original purchase due to internal corrosion, provided the tank is used solely <br /> with or without tank water bottoms for gasoline,gasohol(90%gasoline/10%ethanol mixture),90.5%gasoline and 9.5%Oxinol-50' <br /> (4.75%methanol and 4.75%GTBA mixture),jet fuel,av-gas,kerosene,diesel fuel,motor oil,or potable water at ambient undergound <br /> temperatures;or used for fuel oil at temperatures not to exceed 150°F. <br /> (3)Will not fail for a period of thirty(30)years from date of original purchase due to structural failure(defined as breaking or collapse) <br /> provided the installation is performed and validated by a qualified installation contractor and the tank is used as stated above. <br /> (4)Will meet our published specifications and will be free from material defects in materials and workmanship for a period of one(1)year <br /> following date of original delivery by us. <br /> Xerxes Corporation's liability under this warranty shall be limited to, at our option, (a) repair of the defective tank, (b) delivery of a <br /> replacement tank to the point of original delivery,or(c)refund of the original purchase price,and we shall not be liable for any labor,other <br /> installation costs,indirect or consequential damages or other damages in connection with such tanks.THE FOREGOING CONSTITUTES <br /> OUR EXCLUSIVE OBLIGATION AND WE MAKE NO EXPRESS OR IMPLIED WARRANTIES,OR ANY WARRANTY OF MERCHANT- <br /> ABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHATSOEVER,EXCEPT AS STATED ABOVE. <br /> XERXES PLANT LOCATIONS XERXES CORPORATE OFFICE <br /> 34250 Mills Road 2001 Proform Road 351 North Virginia Avenue 7901 Xerxes Avenue South <br /> Avon,OH 44011 Seguin,TX 78155 P.O. Box 99 Minneapolis, MN 55431 <br /> (216)327-6051 (512)372-0090 Penns Grove, NJ 08069 (612)887-1890 <br /> (609)299-0632 <br /> Building 316 Airport 1210 N.Tustin Avenue <br /> Industrial Park P.O. Box 6069 <br /> P.O. Box 469 Anaheim,CA 92806 <br /> Bartow, FL 33830 (714)630-0012 <br /> (813)533-9047 These instructions supercede an previous editions <br /> XERXES" I HEE:°°�ESS° s-M- <br /> CORPORATION v,E <br />