My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
255
>
2300 - Underground Storage Tank Program
>
PR0537549
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2021 2:29:35 PM
Creation date
11/8/2018 10:22:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0537549
PE
2351
FACILITY_ID
FA0021617
FACILITY_NAME
HARNEY LANE AMPM
STREET_NUMBER
255
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
062-580-40
CURRENT_STATUS
01
SITE_LOCATION
255 E Harney Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HARNEY\255\PR0537549\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�;1-�,� '(71_ Environmental Health Department <br />SAN J O A Q U I N <br />11_ COUNTY— <br />Underground <br />OUNTY <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />HARNEY LANE AMPM <br />255 E Harney Ln, Lodi <br />June 20, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the 2017 annual monitoring system <br />certification on the July 2017 through May 2018 designated operator monthly inspection report. The DO reports <br />indicate 6/20/17 as the annual date, but the date is actually 6/21/17. During the monthly inspection, the designated <br />operator shall check that all required testing and maintenance for the UST system have been completed and <br />document the dates they were done. Ensure that designated operators performing monthly inspections at this <br />facility are including all of the required information on the reports. <br />The designated operator failed to document all the alarms from the attached alarm history on the 11 /30/17 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: L13 UDC 13/14 Low liquid fuel alarm on 11/28/17 and 11/19/17. During the monthly <br />inspection, the designated operator shall review the alarm history for the previous month, check that each alarm <br />was documented and responded to appropriately, and attach a copy of the alarm history with documentation taken <br />in response to any alarms to the monthly report. Ensure that designated operators performing monthly inspections <br />at this facility are including all of the required information on the reports. <br />This is a repeat violation, Class II. <br />309 <br />CCR 2636(0(1) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product. <br />The diesel -grade STP 208 sump sensor failed to activate an audible and visual alarm when tested to ensure <br />continuous monitoring of the tank system. All monitoring equipment shall be maintained to activate an audible and <br />visual alarm or stop the flow of product at the dispenser when it detects a leak. The sensor was replaced and <br />retested during the inspection. A "UST Retrofit Verification with Inspector Already Onsite" form has been completed <br />and provided to the operator and contractor. This was corrected onsite. <br />The L11 UDC 9/10, and L12 UDC 11/12 304 brine sensor were verified to be functional and passed testing. The <br />problem with the sensors are that they were not able to go out of alarm, which needs to be addressed. All <br />monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of product at the <br />dispenser when it detects a leak. Correct immediately by having a properly licensed, trained, and certified <br />contractor replace the failed component with a functional component (LG 113-x listed, if applicable) and obtain a <br />permit from the EHD if necessary. The monitoring system certification was completed on 6/29/18. During this time, <br />the two sensors were replaced while inspector was present. A "UST Retrofit Verification with Inspector Already <br />Onsite" form has been completed and provided to the operator and contractor. This was corrected onsite on <br />6/29/18. <br />This is a minor violation. <br />FA0021617 PR0537549 SC001 06/20/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 4 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.