Laserfiche WebLink
17. Testing fluid Unleaded <br />t8. (a) THE UNDERGROUND STORAGE TANK SYSTEM CERTIFIED TIGHT AT PRODUCT <br />HEIGHT EQUAL TO THE GRADE LEVEL. Yes. <br />(b) Allowable leak resolution of instrumentation or allowable change <br />per California Administrative Code Title 23 Waters, Chapter 3 <br />Water Resources Control Board Subchapter 16 Underground Storage <br />Regulations, ParL 2643 (b), Page 4.14; 0.05 gallons per hour. <br />K** (c) MEASURED HOURLY CHANGE: LOSS (+) OR GAIN (-) GALLONS OR <br />NUMERICAL LEAK RATE IS: -0.006 Gal/Hr. <br />------------------------------------------------------------- <br />This measurement is within the legal. limits as defined in (b). <br />NDE TECHNOLOGY, INC. PROPRIETARY <br />WATT INC. 3131 FAIRHAVEN DRIVE, BAKERSFIELD, CA 93308 (805) 322--9827 <br />NDE'S VPLT COMPUTERIZED TANK TESTING SYSTEM Patent Pending <br />PRECISION UNDERGROUND TANK <br />TESTING RESULTS AND CERTIFICATION <br />PAGE 1, GENERAL REPORT FORM - Copyright .1985 <br />NDE TECHNOLOGY, INC. PROPRIETARY W, <br />TEST <br />DATE: 11/28/1988 <br />-" <br />1. <br />Owner of storage tanks <br />STATE OF CALIFORNIA E� <br />Department of Correctidi�sN <br />Company Representative <br />Cody Begley <br />Title <br />Project Manager <br />2. <br />Mailing address of owner <br />Department of General Services <br />Office of the State Architect <br />P. 0. Box 1079 <br />Sacramento, CA 95812 <br />3. <br />Phone of owner <br />(916) 322-8249 <br />4. <br />STATION NUMBER <br />Deuel Vocational Institute <br />Location and address of <br />23500 Kasson Road <br />the tanks <br />Tracy, CA 95376 <br />Phone number <br />(209) 466-8055 Ext. 4240 <br />Regulatory Agency <br />County of San Joaquin <br />5. <br />TANK DESIGNATION OR ID S <br />R -DVI -06 <br />6. <br />Date each tank was tested <br />11/28/1988 <br />7. <br />The name of the test method <br />VPLT COMPUTERIZED TANK TESTING SYSTEM <br />8. <br />Business name of tank <br />testing company <br />WESTERN AMERICA TANK TESTING, INC. <br />9. <br />Mailing address of tank <br />3131 FAIRHAVEN DRIVE <br />testing company <br />BAKERSFIELD, CA 93308 <br />10. <br />Person conducting test <br />Bob Myrann (TECHNICIAN) <br />and completing report <br />11. <br />Station Operator or <br />Bob Crump <br />manager <br />12. <br />Phone number <br />(209) 466-8055 Ext. 4240 <br />13. <br />Owner name and <br />STATE OF CALIFORNIA <br />title <br />Department of Corrections <br />14. <br />Capacity of the tank <br />2,000 gallons <br />15. <br />Present or past contents <br />Unleaded <br />16. <br />Tank construction material <br />Steel <br />17. Testing fluid Unleaded <br />t8. (a) THE UNDERGROUND STORAGE TANK SYSTEM CERTIFIED TIGHT AT PRODUCT <br />HEIGHT EQUAL TO THE GRADE LEVEL. Yes. <br />(b) Allowable leak resolution of instrumentation or allowable change <br />per California Administrative Code Title 23 Waters, Chapter 3 <br />Water Resources Control Board Subchapter 16 Underground Storage <br />Regulations, ParL 2643 (b), Page 4.14; 0.05 gallons per hour. <br />K** (c) MEASURED HOURLY CHANGE: LOSS (+) OR GAIN (-) GALLONS OR <br />NUMERICAL LEAK RATE IS: -0.006 Gal/Hr. <br />------------------------------------------------------------- <br />This measurement is within the legal. limits as defined in (b). <br />NDE TECHNOLOGY, INC. PROPRIETARY <br />WATT INC. 3131 FAIRHAVEN DRIVE, BAKERSFIELD, CA 93308 (805) 322--9827 <br />