My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2300 - Underground Storage Tank Program
>
PR0231636
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2021 1:16:42 PM
Creation date
11/8/2018 10:22:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231636
PE
2381
FACILITY_ID
FA0003869
FACILITY_NAME
DEUEL VOCATIONAL INSTITUTION*
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23912001
CURRENT_STATUS
02
SITE_LOCATION
23500 KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\K\KASSON\23500\PR0231636\COMPLIANCE INFO 1986 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 1986 - 2015
QuestysRecordDate
10/10/2017 4:11:16 PM
QuestysRecordID
175458
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r„ . APPENDIX B - Page 11.3 <br />3. The TLM will be able to detect (in the tank integrity mode) a minimum <br />of a 0.20 gallon per hour leak while compensating for temperature <br />changes within the tank with a probability of leak detection of 95 <br />percent and probability of false alarms of 5 percent; <br />4. The TLM system will be Level TRU (Model No. 10600) by Environment and <br />Safety, Inc., Veeder-Root TLS -350 with magnetostrictive probe, or <br />equal; <br />5. Install overspill protection device at each tank. The overspill <br />protection device will be Skyway (Model No. 85000), Emco Wheaton <br />A1003, or equal; <br />6. No pipeline leak detector is required because both pumps are suction -type; <br />7. Install only one check valve in the suction line directly below and <br />as close as practical to the suction pump. Remove any other existing <br />check valves. <br />GROUNDWATER <br />This facility is located in the San Joaquin Valley Groundwater Basin. There <br />is one groundwater well located approximately 0.2 miles south of the facility. <br />According to facility personnel, the local groundwater table elevation varies <br />between 3 and 6 feet below the ground surface. <br />