Laserfiche WebLink
NUE'S V1'G9' CCMPUTSR ZED 'TANK 'TlaSTING SYSTEM hiLot►I. Pan►ling <br />EYRUS10N UNDERROUND TANK <br />TLSTIH RESULTS AND CHITIFICATION <br />PAGE 1, GENERAL REPORT FORM - Copyright 1985 <br />NDE TECHNOLOGY, INC. PROPRIETARY <br />TEST <br />DATE: 11/29/1988. <br />1. <br />Owner of storage tanks <br />STATE OF CALIFORNIA%,' <br />Department of Correc�oons <br />Company Representative <br />Cody Begley <br />Title <br />Project. Manager <br />2. <br />Mailing address of owner <br />Department of General S'\erp'Ic_e's <br />Office of the State Architect <br />P. 0. Box 1079 <br />Sacramento, CA 95812 <br />3. <br />Phone of owner <br />(916) 322-8249 <br />4. <br />STATION NUMBER <br />Deuel Vocational Institute <br />Location and address of <br />23500 Kasson Road <br />the tanks <br />Tracy, CA 95376 <br />Phone number <br />(209) 466-80.55 Ext. 4240 <br />Regulatory Agency <br />County of San Joaquin <br />5. <br />TANK DESIGNATION OR ID # <br />R -DVI -05 <br />6. <br />Date each tank was tested <br />11/29/1988 <br />7. <br />The name of the test method <br />VPLT COMPUTERIZED TANK TESTING SYSTEM <br />8. <br />Business name: of tank <br />testing company <br />WESTERN AMERICA TANK TESTING, INC. <br />9. <br />Mailing address of tank <br />3131 FAIRHAVEN DRIVE <br />testing company <br />BAKERSFIELD, CA 93308 <br />10. <br />Person conducting test <br />Bob Myrann (TECHNICIAN) <br />and completing report <br />11. <br />Station Operator or <br />Bob Crump <br />12. <br />manager <br />Phone number <br />(209) 466-8055 Ext. 4240 <br />13. <br />Owner name and <br />STATE OF CALIFORNIA <br />title <br />Department, of Corrections <br />14. <br />Capacity of the tank <br />350 gallons <br />15. <br />Present or past contents <br />Diesel <br />16. <br />Tank construction material <br />Steel <br />17. <br />Testing fluid <br />Diesel <br />18. <br />(a) THE UNDERGROUND STORAGE <br />TANK SYSTEM CERTIFIED TIGHT AT PRODUCT <br />HEIGHT EQUAL TO THE GRADE <br />leak <br />LEVEL. Yes. <br />of instrumentation or allowable change <br />(b) Allowable resolution <br />California Administrative <br />Code Title 23 Waters, Chapter 3 <br />per <br />Water Resources Control <br />Board Subchapter• 16 Underground Storage <br />Regulations, Part 2643 <br />(b), Page 4.14; 0.05 gallons per hour. <br />GALLONS OR <br />*#k <br />(c) MEASURED HOURLY CHANGE: <br />LOSS (+) OR GAIN (-) <br />NUMERICAL LEAK RATE IS: <br />+0.029 Gal/Hr. --L <br />--- ---------- <br />This measurement is within <br />---------------- <br />the legal limits as defined in (b). <br />NDE TECHNOLOGY, INC. PROPRIETARY <br />WATT INC. 3131 FAIRHAVEN DRIVE, <br />BAKERSFIELD, CA 93308 (805) 322-9827 / <br />