My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1999
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
420
>
2300 - Underground Storage Tank Program
>
PR0231906
>
INSTALL_1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/8/2021 4:35:17 PM
Creation date
11/8/2018 10:22:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1999
RECORD_ID
PR0231906
PE
2361
FACILITY_ID
FA0003776
FACILITY_NAME
KWIK SERV*
STREET_NUMBER
420
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06202042
CURRENT_STATUS
01
SITE_LOCATION
420 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\K\KETTLEMAN\420\PR0231906\1999 INSTALL .PDF
QuestysFileName
1999 INSTALL
QuestysRecordDate
5/22/2017 6:23:34 PM
QuestysRecordID
3392091
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-� <br />EXISTING POWER EXISTING 400A MAIN EXISTING PAY PHONE <br />1 <br />SERVICE TO REMAIN TO REMAIN TYP. OF 2 <br />1 POLE TO REMAIN (120/24OV, 30,4W)EXISTING ( ) <br />I ° TANK TO REMAIN <br />NE <br />----- <br />1' 1 <br />1 <br />i <br />I <br />I <br />1 B-6,8 <br />1 3/4"C-2#10 <br />+GND <br />(( I 8 <br />I 1 <br />EXISTING ICE <br />MERCHANDISER <br />TO REMAIN <br />12 NEW CO <br />REPLACE <br />0 <br />NEW UNDERGROUND - <br />FUEL STORAGE (TYP.) <br />0 <br />B <br />LUBE BAY <br />OFFIA<� - � L51 <br />SALES AREA <br />II <br />CARWASH ate® <br />II <br />\ II <br />\\j I <br />II <br />11 <br />II <br />11 <br />II <br />11 <br />II <br />11 ® I <br />II <br />NEW DIESEL FUEL --2 <br />DISPENSER <br />J 3 <br />1 <br />I <br />I <br />1 I I <br />I <br />0 <br />11 <br />III <br />I. <br />1 <br />1 <br />I 0 <br />I� <br />I <br />I <br />i <br />I <br />I <br />I <br />I <br />� u I <br />�7B�114 16 <br />31A"C-2#10I <br />-10,12 9 <br />7TIi'O <br />.3/4"C-2#10 <br />+GND <br />ING CANOPYEMAIN <br />(EX.) RELOCATED <br />MULTI -PRODUCT <br />FUEL DISPENSER <br />(TYP. OF 4) <br />N <br />=_Aill1_-_-s-- <br />0 <br />KETTLEMAN <br />I <br />I <br />0, NORTH <br />_ 10 5 0 10 20 <br />FEET <br />1 Y_ 1-00 <br />SCAL <br />f=lPacific General, Inc. <br />G ENGINEERING/ARCHITECTURAL SERVICES <br />23331 EI Toro Road Suite 217 <br />Lake Forest, California 92630 <br />TEL: (714) 770-2770 • FAX: (714) 770-1252 <br />DESIGNED: <br />R.M.L. <br />DRAWN BY: <br />J.O. <br />CHECKED BY: <br />R.M.L. <br />PROJECT NO. <br />5AS05 <br />FILE NO. <br />SITE PLAN GENERAL NOTES <br />1. INSULATION OF CONDUCTORS IN AND UNDER GASOLINE PUMP AREA <br />SHALL BE LISTED AND APPROVED FOR GASOLINE/OIL RESISTANT TYPE. <br />2. USE EXISTING UNDERGROUND CONDUITS WHERE APPLICABLE AND <br />PERMITTED BY CODES, CONTRACTOR TO VERIFY REQUIREMENTS. <br />3. CONTRACTOR TO VERIFY VOLTAGE OF EXISTING EQUIPMENT TO BE <br />RECONNECTED OR EQUIPMENT FURNISHED BY OTHERS, PRIOR TO <br />HOOK—UP. ANY DISCREPANCY BETWEEN EQUIPMENT AND PLANS <br />BE CALLED TO THE ATTENTION OF THE ENGINEER. <br />4. ALL SITE CONDUCTORS SHALL BE #10 THWN CU., UNLESS NOTED <br />OTHERWISE. <br />5. CONTRACTOR SHALL VERIFY QUANTITY AND SIZE OF ALL CONTROL WIRES. <br />6. COORDINATE EXACT LOCATION FOR P.O.S. EQUIPMENT AND PROVIDE <br />ALL REQUIREMENTS FOR NEW DISPENSERS INSTALLED. <br />7, MINIMUM SITE CONDUIT SIZE SHALL BE 3/4" U.O.N.. PROVIDE PULL— <br />WIRE IN ALL CONDUIT ONLY (C.O.) RUNS. USE RGS UNDERGROUND <br />AND AT DISPENSERS. USE RGS WHERE EXPOSED AND SUBJECT TO <br />PHYSICAL ABUSE. USE RGS, EMT, OR FLEXIBLE CONDUIT IN BUILDING <br />USE LIQUIDLIGHT FLEX AT CONNECTION TO MOTORS. <br />SITE PLAN KEY NOTES <br />DAREA HIGHLIGHTED IS A CLASS 1, DIVISION 2 HAZARDOUS AREA, AND <br />SHALL CONFORM TO NEC ART, 500, 501, 514, AND NFPA 30A. <br />ALL CONDUITS ENTERING OR LEAVING THIS AREA SHALL HAVE <br />SEAL -OFF FITTINGS ON BOTH ENDS OF THE RUN. <br />PROVIDE AND INSTALL ONE (1) EXPLOSION PROOF JUNCTION BOX <br />WITHIN EACH FUEL DISPENSER FOR DISPENSER POWER, LIGHT, CONTROL, <br />SIGNAL MONITORING, AND CARD READER. CONTRACTOR TO MAKE <br />CONNECTION TO FUEL DISPENSER PUMP AND LIGHTS. VERIFY <br />REQUIREMENTS AND COMPLY. <br />(2) 3/4"C (ONE FOR DISPENSER POWER & LIGHT WITH CONDUCTORS: <br />ONE FOR DISPENSER CONTROL/MONITORING/CARD READER WITH <br />CONTROL WIRES) AND (1)1"C (SPARE WITH PULL -STRING) TO ELECTRICAL <br />GUTTER IN LUBE BAY AREA. USE EXISTING CONDUITS WHERE APPLICABLE <br />AND PERMITTED BY CODES. VERIFY REQUIREMENTS, CAND COMPLY. <br />®PROVIDE AND INSTALL NEW SUB -PANEL FOR NEW MULTI -PRODUCT <br />FUEL DISPENSERS AND UNDERGROUND TANKS. SEE PANEL SCHEDULE <br />ON DWG. "E1" FOR ADDITIONAL REQUIREMENTS. <br />EXISTING MAIN ELECTRICAL PANEL "A" TO REMAIN. MODIFY CIRCUITS <br />AS SHOWN ON PANEL SCHEDULE, SEE DWG. 1-1". <br />©REPLACE EXISTING FUEL TANK AND DISPENSER CONTROL AND <br />MONITORING UNITS WHERE REQUIRED. VERIFY AND COMPLY TO ALL <br />REQUIREMENTS. <br />RELOCATE EXISTING TIME CARD MACHINE FROM LUBE BAY AREA TO <br />UTILITY ROOM AS SHOWN TO ACCOMMODATE NEW SUB -PANEL "B" <br />(FOR FUEL TANKS & DISPENSERS). VERIFY REQUIREMENTS. <br />® PROVIDE AND INSTALL J -BOX FOR TANK TURBINE POWER, <br />FEEDERS WIRED THROUGH PUMP RELAY STARTER. VERIFY ALL <br />REQUIREMENTS. <br />10 PROVIDE AND INSTALL J—BOX FOR TANKS SENSOR, MONITOR & <br />LEAK DETECTOR. VERIFY REQUIREMENTS. <br />11 (1) 3/4"C f LOW—VOLTAGE CONTROL WIRES TO MAIN FUEL CONTROL <br />PANEL GUTTER. VERIFY QUANTITY AND TYPE OF WIRES WITH EQUIPMENT <br />PLAN. <br />12 NEW 'DRESSER WAYNE —PLUS 3" TO REPLACE EXISTING "GILBARCO" <br />CONSOLE. RECONNECT POWER. VERIFY LOCATION AT SITE. <br />13 3/4"C WITH LOW—VOLTAGE CONTROL WIRES. VERIFY QUANTITY AND <br />TYPE OF WIRES WITH EQUIPMENT PLANS, <br />RtVISIUNS <br />NO.DATE BY COMMENTS SHELL OIL COMPANY <br />I - HOUSTON, TEXAS <br />- ELECTRICAL SITE PLAN <br />PLANS PREPARED BY. <br />420 W. <br />KETTLEMAN <br />LANE & HUTCHINS STREET <br />A & S ENGINEERING <br />LODI, <br />CALIFORNIA <br />PLANNING ENGINEERING CONSTRUCTION MANAGEMENT <br />SCALE: <br />1"=10'-0" <br />WIC # 204-4416-02C <br />45 QUAIL COURT, SUITE 303 <br />WALNUT CREEK, CALIFORNIA 94596 <br />DATE: <br />10_16-98 <br />DRAWING N0. E2 <br />�-� - PHONE: 510-933-0578 FAX: 510-933-0588 <br />SHEET OF <br />
The URL can be used to link to this page
Your browser does not support the video tag.