LEADER <br />RISER VENT SENSOR CAI <br />(SEENOTE)� II / CABLE GRIP <br />PIPE <br />CAP <br />4"® <br />INTERNALLY <br />INTRINSICALLY THREADED <br />SAFE SENSOR <br />ADJUSTABLE <br />S3 LEAD CABLE <br />NOTE: <br />INSTALL 1/4 POLYFLOW TUBE TO GRADE <br />IF GROUND WATER MAY EXCEED RISER HEIGHT <br />RISER PIPE CAP JUNCTION <br />AND FITTINGS BOX <br />2" THREAOEO TO BLDG <br />PVC OR ABS--,, <br />\ PIPE RISER <br />RISER PIPE <br />FRP RESER <br />FLEXIBLE CONDUIT <br />2" PVC SLIP ON THREADED CAP <br />DO NOT FASTEN PERMANENTLY <br />r 2- THREADED AS NEETEDOS MPC RISER <br />OPEN AT 3 <br />SEAL OFF <br />:: ATTACH TO ADDITIONAL <br />CONDUIT <br />TO LEAK <br />IN <br />DOUBLEWALL FIBERGLASS TANK <br />RESERVIOR S3 <br />SENSOR <br />INTRINSICALLY S2 <br />SAFE SENSOR <br />PRODUCT SHEAR <br />18" TO 24" <br />FLAME ARRESTING <br />FOAM BARRIER lylll\ <br />(cut owoy <br />DISPENSER <br />FRAME <br />JUNCTION BOX <br />NOTES: <br />• SEE NOTE #1 ON D-97004. INSURE COMPLIANCE. <br />• ELECTRONIC MONITORING SYSTEMS (PER "APPROVED MATERIALS LIST') PROVIDES <br />ADVANCED AUTOMATIC CONTROL OF UNDERGROUND TANK AND PIPING INSTALLATIONS. <br />EACH MONITORING SYSTEM CAN BE CONFIGURED TO PROVIDE SIMULTANEOUS REAL <br />TIME SURVEILLANCE OF SEVERAL DIFFERENT INSTALLATION PARAMETERS WITH <br />AUTOMATIC ALARM NOTIFICATION AND AUTOMATIC SHUTDOWN OF SELECTED COMPONENTS <br />IN THE ADVENT OF DEVIATIONS FROM INTENDED OPERATIONS, SENSOR DESCRIPTIONS <br />AND CLASSIFICATIONS ARE NOTED BELOW. <br />S2 CONTINUOUS MONITORING OF SECONDARY CONTAINMENT PIPING AND TURBINE <br />SUMP FOR INTRUSION OF ANY LIQUID. SENSOR IS TO BE INSTALLED SUCH <br />THAT ANY ALARM WILL SHUT DOWN TURBINE IF LIQUID IS DETECTED. SENSOR <br />IS MANDATORY. <br />53 DOUBLE WALL FIBERGLASS TANKS - <br />CONTINUOUS SIMULTANEOUS MONITORING OF TANK INNER AND OUTER WALLS <br />° BY HYDROSTATIC MEANS. IF INTERSTITIAL LIQUID (WATER OR SALT BRINE) <br />LEVEL GOES UP OR DOWN BEYOND LIMITS, SENSOR WILL ALARM BUT SHUT <br />NOTHING DOWN AS SUCH ACTION WILL NOT ARREST THE PROBLEM. HOWEVER, <br />t _ TINTERSTITIAL LIQUID WILL NOT PERMIT PRODUCT TO ESCAPE DUE TO HIGHER <br />RK LEVEL. DENSITY IS MANDATORHER Y' <br />HYDROSTATIC SUCH <br />IC HEAD TANKS,REGARDLESS OF INVENTORY <br />r7� LEVEL. SENSOR IS MANDATORY FOR SUCH TANKS. <br />A A <br />S2 <br />6" OR 8" CONTAINMENT <br />r <br />d' GAILY RISER <br />TANK <br />1" CONDUIT <br />SEE DRWG <br />D-97005 <br />CONTAINMENT <br />SUMP <br />SUMP BOTTOM <br />MUST SLOPE <br />DOWN TOWARDS <br />SENSOR WELL <br />TYPICAL DISPENSER <br />"VEEDER ROOT DISPENSER <br />CONTAINMENT BOX SUMP <br />SENSOR IS TO BE INSTALLED <br />FOR EACH DISPENSER <br />NOTE! <br />SEE COMPARTMENT TANK DETAILS FOR <br />ACTUAL TANK TOP EQUIPMENT LAYOUT. <br />TYPICAL DOUBLEWALL FIBERGLASS TANK <br />S4 CONTINUOUS MONITORING OF TANK RISER INTERSTITUAL, IF RISERS ARE CONTAINED. <br />SENSOR WILL AUTOMATICALLY ALARM IF ANY LIQUID INTRUDES INTO INTERSTITUAL, <br />BUT WILL SHUT NOTHING DOWN AS SUCH WILL NOT ARREST THE PROBLEM. <br />SENSOR IS OPTIONAL. HOWEVER, IF RISERS ARE CONTAINED, SENSOR CONDUITS <br />MUST ALSO BE INSTALLED FOR POSSIBLE FUTURE USE. SINCE CONDUITS ARE <br />PART OF SAID CONTAINMENT, SAID CONDUITS MUST PASS BOTH N.E.C. CONTINUITY <br />TEST AND PRESSURIZED LEAK TEST, <br />SS CONTINUOUS PRODUCT INVENTORY LEVEL MONITORING, CAN BE PROGRAMMED <br />TO PROVIDE LOW INVENTORY LEVEL WARNING, HIGH INVENTORY LEVEL ALARM, <br />WATER WARNING, AND AUTOMATIC TANK LEAK TEST TO .01 GPH ACCURACY PER <br />USEPA PROTOCOL. SENSOR IS OPTIONAL BUT CONDUITS FOR SENSOR MUST <br />BE INSTALLED AND MUST PASS BOTH AN N.E.C. CONTINUITY TEST AND A <br />PRESSURIZED LEAK TEST. <br />S6 CONTINUOUS MONITORING OF DISPENSER SECONDARY CONTAINMENT SPACE FOR <br />INTRUSION BY ANY LIQUID. SENSOR WILL AUTOMATICALLY ALARM AND SHUT DOWN <br />OFFENDING DISPENSER (NO ELECTRICAL POWER TO SAID DISPENSER) SHOULD <br />ANY LIQUID BE DETECTED. SENSOR IS MANDATORY. <br />SO... ADDITIONAL SENSORS CAN BE UTILIZED, BUT MUST FIRST BE APPROVED BY <br />HEAD OFFICE MARKETING ENGINEERING STAFF UNLESS GENERAL SPECIFICATIONS <br />OR "APPROVED MATERIALS LIST' IS REVISED TO SHOW APPROVALS OF SAME IN <br />THE FUTURE. <br />• ALL SENSITIVE CIRCUITS (SENSORS, DATA, ETC) SHALL BE ROUTED IN METALLIC <br />CONDUIT AROUND (NOT THROUGH) WIRE TROUGH IN BUILDINGS. FAILURE TO COMPLY <br />MAY CAUSE SYSTEMS TO PICK UP INDUCTIVE NOISE THAT DISRUPTS INTENDED <br />OPERATION OF SENSITIVE DEVICES. <br />Shell 011 Company. All Riqhts Reserved 1997 <br />