Laserfiche WebLink
'�soo ce <br />N! <br />N%i STATE OF CALIFORNIA <br />STATE WATER RESOURCES CONTROL BOARD <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B a .o <br />OnMPI FTE A SEPARATE FORM FOR EACH TANK SYSTEM <br />MARK ONLY ❑ 1 NEW PERMIT ❑ <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ <br />3 RENEWAL PERMIT <br />4 AMENDED PERMIT <br />5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br />❑ 6 TEMPORARY TANK CLOSURE ❑ a TANK REMOVED /` <br />J <br />DBAOR FACILITY NAME WHERE TANK IS INSTALLED: <br />B. <br />�1 PRODUCT <br />EADED <br />❑ OL 7 METHANOL <br />1b PREMIUED <br />❑ 2 PETROLEUM ❑ 60 EMPTY <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNUWN <br />A OWNER'S TANK 1 D # O �, B. MANUFACTURED BY: Vn DA/d <br />C DATE INSTALLED (MO/DAYNEAR) Vn �-or7✓ �l D. TANK CAPACITY IN GALLONS. o' 000 <br />II. T ANY, CONTENTS 14A-1 IS <br />__..__... _.._.__... <br />G AR 3 DIESEL ❑ 6 AVIATION GAS <br />C. ❑ 1aUN <br />A MOTOR VEHICLE FUEL ❑ 4 OIL <br />B. <br />�1 PRODUCT <br />EADED <br />❑ OL 7 METHANOL <br />1b PREMIUED <br />❑ 2 PETROLEUM ❑ 60 EMPTY <br />% UNKNOWN <br />❑ ❑ 5 EATFUEL <br />UNLEAD❑ <br />3 CHEMICALPRODUCT ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C. A. S. # : <br />unTnunTrn atAnln AI I TWAT AV PI IFS IN Pnr n ANn F <br />M. imV� <br />__..__... _.._.__... <br />_ <br />1 SUCTION <br />A <br />❑ 1 DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR LINER <br />% UNKNOWN <br />A. TYPE OF <br />SYSTEM <br />❑ 2 SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) <br />❑ 99 OTHER <br />A U <br />❑ 1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEELCLAD W/ FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ 5 CONCRETE <br />6 POLYVINYL CHLORIDE <br />E]M <br />❑ 7 ALUMINUM <br />❑ 8 100% METHANOL COMPATIBLE W/FRP <br />(PrimaryTank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />�5 UNKNOWN <br />❑ 99 OTHER <br />5 ALUMINUM <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />❑ 5 GLASS LINING <br />❑ 6 UNLINED <br />[ 95 UNKNOWN <br />❑ 99 OTHER <br />LINING <br />10 CATHODIC PROTECTION <br />ADS UNKNOWN <br />A U <br />99 OTHER <br />D. <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES_ NO— <br />DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 3 <br />D. CORROSION <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />F--] 3 VINYL WRAP <br />4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />❑-95 UNKNOWN <br />❑ 99 OTHER <br />E. SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND, BOTH IF APPLICABLE <br />A. <br />SYSTEM TYPE <br />A U <br />1 SUCTION <br />A <br />2 PRESSURE A U <br />3 GRAVITY <br />A U 99 OTHER <br />B. <br />CONSTRUCTION <br />A U <br />1 SINGLE WALL <br />A U <br />2 DOUBLE WALL A U <br />3 LINED TRENCH <br />A 5 UNKNOWN A U 99 OTHER <br />C. <br />MATERIAL AND <br />A U <br />1 BARE STEEL <br />A U <br />2 STAINLESS STEEL A U <br />3 POLYVINYL CHLORIDE (PVC) A U <br />4 FIBERGLASS PIPE <br />CORROSION <br />A U <br />5 ALUMINUM <br />A U <br />6 CONCRETE A U <br />7 STEEL W/COATING <br />A U <br />8 100% METHANOL COMPATIBLE W/FRP <br />PROTECTION <br />A U <br />9 GALVANIZED STEEL <br />A U <br />10 CATHODIC PROTECTION <br />ADS UNKNOWN <br />A U <br />99 OTHER <br />D. <br />LEAK DETECTION <br />1 AUTOMATIC LINE LEAK <br />DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 3 <br />❑ 99 OTHER <br />MONBORING <br />V. TANK LEAK DETECTION <br />❑ 1 VISUAL CHECK L �2 INVENTORY RECONCILIATION D 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br />❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATED DATE LAST USED (MO/DAYNR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br />SUBSTANCE REMAINING GALLONS INERTMATERIAL? YES ❑ NO <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />APPLICANTS NAME DATE <br />(PRINTED A SIGNATURE) <br />LOCAL AGENCY USE ONLY THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION • FORM A, UNLES A CURRENT FORM A HAS BEEN FILED. <br />FINOWBAS <br />COUNTY # <br />JURISDICTION # <br />FACILITY # <br />TANK # <br />15,44 / y <br />STATE I.D.# <br />-3 9 <br />O O 6 3q I <br />► 11, 3 Y c-7 <br />PERMrr NUMBER <br />PERMIT APPROVED BYIDATE <br />PERMIT EXPIRATION DATE �_ <br />9-9�- <br />FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION • FORM A, UNLES A CURRENT FORM A HAS BEEN FILED. <br />FINOWBAS <br />