My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
7611
>
2300 - Underground Storage Tank Program
>
PR0231511
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:35 AM
Creation date
11/8/2018 10:23:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231511
PE
2361
FACILITY_ID
FA0003695
FACILITY_NAME
ESTES TRUCKING
STREET_NUMBER
7611
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17705029
CURRENT_STATUS
01
SITE_LOCATION
7611 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\A\AIRPORT\7611\PR0231511\COMPLIANCE INFO 2017 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
1/23/2018 5:59:54 PM
QuestysRecordID
3769323
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> Facility Name: <br /> ESTES TRUCKING <br /> Facility Address: <br /> 7611 S AIRPORT WAY, STOCKTON, CA 95206 <br /> Facility Phone: <br /> (209) 982-1841 <br /> Program: <br /> 2361 - UST FACILITY <br /> Inspection Type: <br /> ROUTINE INSPECTION - Operating Permit <br /> Date: <br /> May 25, 2018 <br /> CERS ID: <br /> 10181317 <br /> Inspection Contact: <br /> James Monzingo <br /> Consent For: Consent Given By: <br /> Jame Monzingo, Manager <br /> Title: <br /> Manager <br /> Phone: <br /> (209) 982-1841 <br />T Inspection T Photos £ Samples <br />Underground Storage Tank Program Inspection Report <br /> Service Technician Manufacturer's Training: <br /> VR, 08/09/19; VMI, 06/20/18 <br /> Service Technician Onsite: <br /> Ed Stearns <br /> Exp. Date: <br /> 11/09/2018 <br /> Designated Operator: <br /> Zane Nimmo <br /> Exp. Date: <br /> 02/23/2020 <br />R = Repeat violation COS = Corrected on site during inspectionV = Violation <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />File Review <br /> 101 □ V □ R □ COSFailure to obtain a valid permit to operate from the EHD including but not limited to unpaid feesHSC 25284 <br /> 102 □ V □ R □ COSNo written agreement between tank owner and tank operator to monitor the tank systemHSC 25284(a)(3)(A)/(B) <br /> 103 □ V □ R □ COSCurrent financial responsibility documents not submittedHSC 25292.2, 25299.30 <br /> 104 □ V □ R □ COSUST operating permit application for facility and tank information not submitted or currentCCR 2711 <br /> 105 ■ V ■ R □ COSFailed to have an approved UST monitoring planCCR 2632(d)(1), <br />2634(d) <br /> 106 □ V □ R □ COSFailed to have an approved UST response planCCR 2632(d)(2), <br />2634(e) <br /> 107 ■ V ■ R □ COSPlot plan/site map not submitted or failed to completely show where monitoring is performedCCR 2632(d)(1)(C) <br /> 108 □ V □ R □ COSFailed to notify the EHD 48 hours prior to conducting testingCCR 2637(f), 2638(e) <br /> 109 □ V □ R □ COSFailed to test secondary containmentCCR 2637 <br /> 110 □ V □ R □ COSFailed to submit secondary containment test report within 30 daysCCR 2637(e) <br /> 111 □ V □ R □ COSFailed to test monitoring and leak detection equipment annuallyCCR 2638(a) <br /> 112 □ V □ R □ COSFailed to test spill containers annuallyHSC 25284.2 <br /> 113 □ V □ R □ COSFailed to submit monitoring system certification test report within 30 daysCCR 2638(d) <br /> 114 □ V □ R □ COSFailed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut downCCR 2636(f) <br /> 115 □ V □ R □ COSFailed to submit to EHD notification of designated operator identification or change w/in 30 daysCCR 2715(a) <br /> 116 □ V □ R □ COSDesignated operator, service tech or installer did not possess current ICC certificationCCR 2715 <br /> 117 □ V □ R □ COSFailed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years afterCCR 2663(h) <br /> 118 □ V □ R □ COSFailed to submit tank lining certification within 30 days or to conduct proper testsCCR 2663 <br /> 119 □ V □ R □ COSDocuments were falsified or misrepresentedHSC 25299(a)(8), <br />25299(b)(7) <br /> 120 □ V □ R □ COSFailed to submit UST Certification of Installation/ModificationCCR 2635(d) <br /> 121 ■ V □ R □ COSFailed to submit a written response within 30 days of receiving an inspection reportCCR 2712(f) <br /> 122 □ V □ R □ COSFailure to submit and maintain UST system component statement of compatibility for substance storedCCR 2631(j) <br />On Site Records <br /> 201 □ V □ R □ COSFailure to maintain monitoring, maintenance, and follow up action recordsCCR 2712(b) <br />Page 1 of 5 <br />FA0003695 PR0231511 SC001 05/25/2018 <br />EHD 23-01 Rev. 10/31/2017 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.