My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
3011
>
2300 - Underground Storage Tank Program
>
PR0231883
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:52 AM
Creation date
11/8/2018 10:23:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231883
PE
2351
FACILITY_ID
FA0002111
FACILITY_NAME
BEN HOLT SHELL
STREET_NUMBER
3011
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
10018010
CURRENT_STATUS
02
SITE_LOCATION
3011 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\B\BENJAMIN HOLT\3011\PR0231883\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
12/29/2011 8:00:00 AM
QuestysRecordID
104119
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/RI NIFIED PROGRAM CONSOLIDAT EDF <br /> ( <br /> fflQEVgD <br /> JUN 1. 1 [Q�ftllcs <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 Sip'uMvIewMA M A� <br /> VI.PIPING CONSTRUCTION(Ghent ag OWAAply) - <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE X 1. PRESSURE r 2. SUCTION r 3. GMVTTY r 1. PRESSURE r 2. SUCTION r 3. GRAVITY 459 <br /> CONSTRUCTION r 1. SINGLE WALL r 3. LINED TRENCH r 99. OTHER r I. SINGLE WALL 17% UNKNOWN 482 <br /> 7 X 2. DOUBLE WALL r 95. UNKNOWN r 2. DOABLE WALL 1-99 OTHER <br /> MANUFACTURE <br /> R MANUFACTURER 461 MANUFACTURER <br /> 463 <br /> r 1.BARE STEEL r 6. FRP COMPATIBLE N 1009E METHANOL r 1. BARE STEEL r 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND T 2. STAINLESS STEEL r 7- GALVANIZED STEEL r 2. STAINLESS STEEL r ]. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION r 3- PLASTIC COMPATIBLE WITH CONTENTS 17%, UNKNOWN r 3. PLASTIC COMPATIBLE WITH CONTENTS r 8. FLEXIBLE(HDPE) r 99. OTHER <br /> X 4. FIBERGLASS r 8. FLEXIBLE(HOPE) 1799 OTHER r 4. FIBERGLASS r 9. CATHODIC PROTECTION <br /> r5 STEEL W/COATING r9 CATHODIC PROTECTION 464 r5 STEEL We COATING r95 UNKNOWN 465 <br /> VIL PIPING LEAK DETECTION(Check al that appal(A descnpt an oram m mtavinp popram shall 5e s bMftd to M&AMW a9wxy) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 48] <br /> PRESSURIZED PIPING(Check all Mat appyall M <br /> ): PRESSURIZED PIPING(Check at appy). <br /> r 1. ELECTRONIC LINE LEAK DETECTOR 30 GPM TEST NTH AUTO PUMP SHUT OFF FOR r 1. ELECTRONIC LINE LEAK DETECTOR 3 0 GPM TEST WITH AUTO PUMP SHUT OFF FOR LEAK <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION v AUDIBLE AND VISUAL SYSTEM FAILURE.AND SYSTEM DISCONNECTION--AUDIBLE AND VISUAL ALARMS <br /> ALARMS r 2. MONTHLY 0.2 GPM TEST <br /> r 2. MONTHLY 0.2 GRH TEST r 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> r 3 WNUAL INTEGRITY TEST(01 GPM) <br /> r 4 DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS. CONVENTIONAL SUCTION SYSTEMS(Chit m Mat appy)' <br /> r 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM�TRIENNIAL PIPING INTEGRITY r 5. DAILY VISUAL MONITORING OF PIPPING AND PUMPING SYSTEM <br /> TEST(0.1 GPM) r 6. TRIENNIAL INTEGRITY TEST(01 GPM) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING)- SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING). <br /> r 7 SELF MONITORING <br /> r ] SELF MONITORING <br /> GRAVITY FLOW GRAVITY FLOW(Check aI that apply) <br /> r 9 BIENNIAL INTEGRITY TEST(01 GPM) r 8 DAILY VISUAL MONITORING <br /> r 9. BIENNIAL INTEGRITY TEST(01 GPM) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that appy) PRESSURIZED PIPING(Check all Mat appy): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITHAUDIBLE AND VISUAL ALARMS AND <br /> (check acre) 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(dledl oro) <br /> F e AUTO PUMP SHUT OFF WHEN A LEA(OCCURS r a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> X D AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION r b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> F c NO AUTO PUMP SHUT OFF r . NO AUTO PUMP SHUT OFF <br /> X 11 AUTOMATIC LINE LEAK DETECTOR(3 0 GPM TEST)NTH FLOW SHUT OFF OR r 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> r 12 ANNUAL INTEGRITY TEST(0.1 GPM) r 12 ANNUAL INTEGRITY TEST(0.1 GPM) <br /> SUCTIONGRAVITY SYSTEM'. SUCTIONGRAVITY SYSTEM. <br /> r 13. CONTINUOUS SUMP SENSOR a AUDIBLE AND VISUAL ALARMS r 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check ak Mat apply) EMERGENCY GENERATORS ONLY(Chad she MW apply) <br /> r 14 CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND r 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> r 15 AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITHOUT FLOW SHUT OFF OR r 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST) <br /> RESTRICTION <br /> r i6 ANNUAL INTEGRITY TEST(D 1 GPM) r 16. ANNUAL INTEGRITY TEST(01 GPM) <br /> F 17 DAILY VISUAL CHECK r 17 DAILY VISUAL CHECK <br /> VII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT r 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE r 4 DAILY VISUAL CHECK <br /> DATE INSTALLED 468 172 CONTINUOUS DISPENSER PAN SENSOR.AUDIBLE AND VISUAL ALARMS r 5 TRENCH LINER I MONITORING <br /> 1998_X 3 CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS r 6 NONE 469 <br /> I oortdy Ma Bre n.r,,M pn provided heran istrue end afClfaM to dre Dee of my <br /> SK'NA OF OVMIERIOPE17IR DATE 470 <br /> 6#7102 <br /> NMA OWNER/OPERATOR(pnM) 471 TITLE OF OWNER/OPERATOR 472 <br /> Bruce T. Marubashi for Shell Oil Products HSE Analyst 925-76"98 <br /> Penni)Number(For pool use only) 473 I Pe ft Approved(FcrkxW use oray) 474 I P"k fix anmpn Dae(Forlocal use omy) 475 <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.