Laserfiche WebLink
vleeder-Root Sensor Application �'atW6 <br /> Single-Point Mini Hydrostatic Sensor for Double Wall Sumps <br /> The Single-Point Mini Hydrostatic sensor accurately detects fluid level change in the interstice reservoir of a dou- <br /> ble-wall sump. If a leak occurs in the sump interstice, the brine seeps out of the reservoir triggering a low level <br /> alarm. An open sensor triggers a Sensor Out alarm. <br /> Table 16. Mini Hydrostatic Reservoir Sensor Features and Console Compatibility <br /> Item Description <br /> Form number 794380-304(8 foot[2.4m]cable) <br /> Operating principle Float switch <br /> Product activation height' 0.793"(2cm) <br /> Reservoir solutions Up to 506 ethylene glycol in water;up to 5M6 propylene glycol in water;salt brine solution of up to 30%CaCI <br /> Operating temperature -13 to +122°F(-25 to +50°C) <br /> Dimensions 2.5"(6.4cm)high,1.5"(3.8cm)dia. <br /> Compatible consoles TLS-450/TLS-450PLUS,TLS4/8601 Series,TLS-350 Series,TLS-300 Series <br /> Console Interface TLS-300 Series-no input module required <br /> Module <br /> TLS-350 Series,Interstitial/Liquid Sensor Interface Module,8 sensor input,P/N 329358-001 <br /> TLS-450/TLS-450PLUS-Universal Sensor Module(USM),16 sensor input,P/N 332812-001 <br /> TLS4/8601 Series-Universal Sensor Input Output Module(USIOM)(AC ver.),12 sensor input,P/N 333238-001;(AC ver.), <br /> 6 sensor input,P/N 333238-002;(DC ver.),12 sensor input,P/N 333238-003;(DC ver.),6 sensor input,P/N 333238-004 <br /> Maximum number of TLS-300 Series(8) <br /> sensors monitored per — -- ----- — <br /> console TLS-350 Series(48) <br /> TLS-450/TLS-450PLUS(32) a __ <br /> TLS4/8601 Series(12) <br /> Compatible fuels 100%Gasoline and blends with up to 1546 Ethanol;Diesel;Bio-Diesel;Kerosene;Jet fuel;Aviation Gas;Waste Oil;Motor <br /> Oil Jr iJ 3" 0018 <br /> 1For additional third party evaluation data see:http:/,,'nwgide.org/'evals/veeder—root—za.htmi <br /> ENVFJIONK "7"ITAL HEALTH <br /> Miscellaneous 4 - ,b T <br /> ® Installation example (see Pig. 13) 4_4 ~`+ <br /> Corcret@` <br /> `. .a Nat,� <br /> a. <br /> Doubtit <br /> sump Sensor in interstitial fluid reservoir fil <br /> Coupling andir <br /> seals as required <br /> for conduit egress , i <br /> (customer supplied)` fit <br /> "R \Seat-off ano;urcticr box Sli <br /> (customer suppiled) <br /> Rigid conduit to .! i <br /> TLS console i Use tie wraps to keep i <br /> I cattle clear of sump <br /> i componen is and lid <br /> r <br /> Tank <br /> F <br /> f <br /> • 13 Example Mini-Hydrostatic <br /> 16 <br />