My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
13975
>
2300 - Underground Storage Tank Program
>
PR0231622
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:27 AM
Creation date
11/8/2018 10:26:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231622
PE
2351
FACILITY_ID
FA0000055
FACILITY_NAME
TESORO (SHELL) 68150 (WRR 6133)
STREET_NUMBER
13975
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
APN
01908014
CURRENT_STATUS
01
SITE_LOCATION
13975 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\E\HWY 88\13975\PR0231622\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
6/2/2014 6:52:07 PM
QuestysRecordID
90861
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IIFIED PROGRAM CONSOLIDATED FO'less, ad <br /> UNDERGROUND STORAGE TANKS - TANK PAGE /` TANKS <br /> (two pages per tank) <br /> Page_of <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for Marl wanly) (specilymeon-forlocalwonly) ❑ 8 TANKREMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: 1 <br /> Tesoro West Coast Company,LLC USA,CC#SS750 b <br /> LOCATION WITHIN SITE(Optional) 431 <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local <br /> a en <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK Yes No 434 <br /> STIP Ill complete one page for each carpaMerr. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 1990 10,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> It.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE <br /> 440 <br /> ®1. MOTOR VEHICLE FUEL 01a. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> y marked conglete Petroleum Type) ❑1b. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> Cl 2. NON-FUEL PETROLEUM ❑ 1c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Haiardous Materials Inventory page) 441 CAS#((ran Heusi Materiels inventory page) 442 <br /> ❑4. HAZARDOUS WASTE UNLEADED FUEL 800-61-9 <br /> (incudes Used Oil) <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑3.SINGLE WALL WITH ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one Mem only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank a 1. BARE STEEL 0 3. FIBERGLASS/PLASTIC 0 5. CONCRETE 95. UNKNOWN 444 <br /> (Check oro item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE W/ ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) 100%METHANOL <br /> TANK MATERIAL-secaMaytrk 1. BARE STEEL 3. FIBERGLASS/PLASTIC 5. CONCRETE 95. UNKNOWN 443 <br /> (Check aro item only) ❑2. STAINLESS STEEL ®4.STEEL CUD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> ❑5. CONCRETE ❑10.COATED STEEL <br /> TANK INTERIOR UNING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check ansa Mem only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check oro Mem only) V2SACRIFICIAL ANODE (For locales only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local Use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> n wars ®1 SPILL CONTAINMENT 1990 <br /> ®1 ALARM UNK ❑3 FILL TUBE SHAT OFF VALVE <br /> ®2 DROP TUBE 1990 ®2 BALL FLOAT LINK ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1990 <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall Its submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all Ihatepply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Checkane item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> +(SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAV) 455 ESTIMATED QUANTITY OF SUBSTANCE 455 TANK FILLED WITH INERT MATERIAL? 457 <br /> REMAINING <br /> gallons ❑Yes ❑ No <br /> UPCF(12/99 revised) Formeriv SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.