My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14000
>
2300 - Underground Storage Tank Program
>
PR0231631
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:33 AM
Creation date
11/8/2018 10:26:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0231631
PE
2361
FACILITY_ID
FA0000091
STREET_NUMBER
14000
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
14000 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\E\HWY 88\14000\PR0231631\COMPLIANCE INFO 2016- PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016- PRESENT
QuestysRecordDate
5/18/2017 8:47:48 PM
QuestysRecordID
3387540
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS-350 <br /> CERTIFICATION / TEST DATE: April 11, 2018 <br /> Al. FACILITY A2. OWNER <br /> Name Colonial Energy#40138 Name Colonial Energy, LLC. <br /> Address 14000 E.Hwy.88,Lockeford,CA 95237 Address 2860 N.Santiago Blvd.2nd Floor,Orange,CA 92867 <br /> Phone# 916-285-7402 Phone# 714-761-5426 <br /> Contact Station Manager Contact Victor Hassan <br /> A3. C U PA A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering,Inc. <br /> Address 1868 E.Hazelton Avenue,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified March 27,2018 Lic# 617238 A,B,Haz <br /> Inspector Aaron Hang Contact Veronica Freitas <br /> Phone# 209-468-3442 Phone# 916-373-1166 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> Bt: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-91 <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-420 ■ Annular Space or Vault Sensor Model: 0794390420 <br /> Piping Sump/Trench Sensor(s) Model: 0794380-208 0 Piping Sump/Trench Sensoria) Model: 0794380-206 <br /> ❑ FIII Sump Sensor(s) Model: ❑ FIII Sump Sensoria) Model: <br /> 0 Mechanical Line Leak Detector Model: FE Petro STP-MLD 0 Mechanical Line Leak Detector Model: FE Petro STP-MLD <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Diesel Tank#4 (Product): <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> • Annular Space or Vault Sensor Model: 0794390420 ❑ Annular Space or Vault Sensor Model: <br /> • Piping Sump/Trench Sensors) Model: 0794380-208 ❑ Piping Sump/Trench Sensors) Model: <br /> ❑ Fill Sump Sensors) Model: ❑ Fill Sump Sensor(s) Model: <br /> E Mechanical Line Leak Detector Model: VMI 99LD-2000 ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> E12: DISPENSERS/UDC's <br /> Dispenser#: 1 .2 Dispenser#: 3-4 <br /> ■ Dispenser Containment Sensoria) Model: 0794380-208 ■ Dispenser Containment Sensors) Model: 0794380-208 <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: 5-6 Dispenser#: 7-8 <br /> 0 Dispenser Containment Sensors) Madel: 0794380-208 N Dispenser Containment Sensors) Model: 0794380-208 <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chains) <br /> Dispenser#: Dispenser#: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Floats)and Chain(s) <br /> C. CERTIFICATION Icertify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing th <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply <br /> /_� ././���.,. �//�/J ■ System set-up ■ Alarm History Report <br /> LTON_- <br /> Signature: / IRY- /✓"'— ---�_ �AENGINEERING,INC. <br /> Technician I Cert#: Anthony Reyes 846116 8293772 Date: April 11, 2018 <br /> ©2018 Walton Engineering,Inc. <br />