My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
701
>
2300 - Underground Storage Tank Program
>
PR0231059
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 4:26:58 PM
Creation date
11/16/2018 11:31:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231059
PE
2361
FACILITY_ID
FA0002512
FACILITY_NAME
GSG GAS & MART
STREET_NUMBER
701
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734311
CURRENT_STATUS
01
SITE_LOCATION
701 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.slcehd.com <br />UNDERGROUND STORAGE TANK <br />UST <br />PROGRAM INSPECTION REPORT <br />Facility <br />Name: A� �" <br />Facility <br />Address: <br />CCR 2712(1) <br />GK <br />Inspection <br />Date: ZO <br />Received <br />By (initial): <br />EHD 23-01 REV 08/07/15 <br />Page 2 <br />Inspector <br />Initial: <br />UST INSPECTION REPORT <br />On Site Records <br />V R COS <br />204 <br />CCR 2712(1) <br />Current monitoring plan approved by the EHD not found on site (V734) <br />:J ❑ ❑ <br />205 <br />CCR 2712(i) <br />Operating permit not on site (V738) <br />❑ ❑ ❑ <br />206 <br />HSC 25294, 25295 <br />Failed to record or report unauthorized release in appropriate time frame (V737) <br />❑ ❑ ❑ <br />207 <br />CCR 2715 <br />Designated operator did not inspect all required items and/or the inspection reports not completed (V723) <br />❑ ❑ ❑ <br />208 <br />CCR 2715 <br />Designated operator monthly inspection reports not maintained on site for at least 12 months (V722) <br />❑ ❑ <br />209 <br />CCR 2715(f) <br />Designated operator employee training not performed or log not kept (V727) <br />❑ ❑ ❑ <br />210 <br />CCR 2715(f)(2) <br />Unstaffed facility failed to have or implement a training program approved by the EHD (V740) <br />❑ ❑ ❑ <br />211 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept (V729) <br />❑ ❑ ❑ <br />212 <br />HSC 25281.5(b)(3) <br />Unburied emergency generator fuel piping not visually inspected at least monthly or log kept (V728) <br />❑ ❑ ❑ <br />Received <br />By (initial): <br />EHD 23-01 REV 08/07/15 <br />Page 2 <br />Inspector <br />Initial: <br />UST INSPECTION REPORT <br />UST System Observations <br />V R" COS <br />301 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills (V715) <br />❑ ❑ ❑ <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary into secondary containment (pre -Jul 2003) (V688) <br />❑ Cl ❑ <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003 -Jun 2004) (V693) <br />❑ ❑ ❑ <br />304 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) (V695) <br />❑ ❑ ❑ <br />305 <br />HSC 25290.1(e) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained (V694) <br />❑ ❑ ❑ <br />306 <br />CCR 2630(d) <br />Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (V691) <br />❑ ❑ <br />307 <br />CCR 2632(c) <br />Monitoring system of the interstitial space of a double walled system not maintained (V679) <br />❑ ❑ ❑ <br />308 <br />CCR 2636(f) <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm (V678) <br />❑ ❑ ❑ <br />309 <br />CCR 2636(f)(1) <br />Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC (V687) <br />❑ ❑ ❑ <br />310 <br />CCR 2636(f)(1) <br />Sensor in a piping sump failed to activate an audible and visual alarm or stop the flow product (V684) <br />❑ ❑ ❑ <br />311 <br />CCR 2636(f)(5) <br />Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs (V683) <br />❑ ❑ ❑ <br />312 <br />CCR 2636 <br />Failed to properly program or operate leak detection equipment (V677) <br />❑ ❑ ❑ <br />313 <br />CCR 2638(f) <br />Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced (V681) <br />❑ ❑ ❑ <br />314 <br />CCR 2631(a) <br />Primary containment not tight (pre -Jul 2003) (V758) <br />❑ ❑ ❑ <br />315 <br />HSC 25290.2(c)(1) <br />Primary containment not tight (Jul 2003 -Jun 2004) (V759) <br />❑ ❑ ❑ <br />316 <br />HSC 25290.1(c)(1) <br />Primary containment not tight (after Jun 2004) (V822) <br />❑ ❑ Cl <br />317 <br />HSC 25290.1, <br />25290.2, 29291 <br />Secondary containment not tight (V710) <br />❑ ❑ ❑ <br />318 <br />CCR 2636(a) <br />Failed to have secondary containment (V706) <br />❑ ❑ ❑ <br />319 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) (V821) <br />❑ Cl ❑ <br />320 <br />HSC 25290.1(c)(3), <br />25290.2 (c)(3) <br />Secondary containment not constructed to prevent water intrusion (V707) <br />❑ ❑ ❑ <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump (V709) <br />❑ ❑ ❑ <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed (V700) <br />❑ ❑ ❑ <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi (V704) <br />❑ ❑ ❑ <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty (V712) <br />❑ ❑ ❑ <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons (V714) <br />❑ ❑ ❑ <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements (V716) <br />❑ ❑ ❑ <br />327 <br />CCR 2635(b)(2) <br />Overfill prevention system was overridden (V845) <br />328 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status (V739) <br />❑ ❑ ❑ <br />329 <br />CCR 2717.1(g) <br />Tampered with red tag (V742) <br />❑ ❑ ❑ <br />Received <br />By (initial): <br />EHD 23-01 REV 08/07/15 <br />Page 2 <br />Inspector <br />Initial: <br />UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.