COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
701
>
2300 - Underground Storage Tank Program
>
PR0231059
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 4:26:58 PM
Creation date
11/16/2018 11:31:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231059
PE
2361
FACILITY_ID
FA0002512
FACILITY_NAME
GSG GAS & MART
STREET_NUMBER
701
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734311
CURRENT_STATUS
01
SITE_LOCATION
701 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r^a slow � <br />Page 3 of 4 <br />San Joaquin County <br />Environmental Health Department JUN 2 2 2015 <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehdINVIRONMENTA <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />SUPER CENTER MART` <br />Facility Address: <br />1701 E DR MARTIN LUTHER KING JR BLVD <br />Date: <br />June 08 2015 <br />UST System Observations <br />319 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />❑ V ❑ R <br />❑ COS <br />320 <br />HSC 25290.1(c3), <br />25290.1(c3) <br />Secondary containment not constructed to prevent water intrusion <br />❑ V ❑ R <br />❑ COS <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />❑ V ❑ R <br />❑ COS <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V ❑ R <br />❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V ❑ R <br />❑ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V ❑ R <br />❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V ❑ R <br />❑ COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />❑ V ❑ R <br />❑ COS <br />327 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V ❑ R <br />❑ COS <br />328 j <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R <br />❑ COS <br />329 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R <br />❑ COS <br />330 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R <br />❑ COS <br />331 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R <br />❑ COS <br />332 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R <br />❑ COS <br />333 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R <br />❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R <br />❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R <br />❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R <br />❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R <br />❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R <br />❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R <br />❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R <br />❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />103 <br />HSC 25292.2 Current financial responsibility documents not submitted. <br />A current financial responsibility document ( UST Letter from Chief Financial Officer) has not been submitted to the <br />EHD. Current financial responsibility documents are required to be submitted annually. Immediately log into the <br />California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents. <br />This is a minor violation. <br />Received by <br />(initial): <br />Inspector: <br />FATINAH ZAREEF, REHS <br />Phone: <br />(209) 953-7311 <br />Date: <br />06/08/2015 <br />Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.