My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
701
>
2300 - Underground Storage Tank Program
>
PR0231059
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 4:26:58 PM
Creation date
11/16/2018 11:31:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231059
PE
2361
FACILITY_ID
FA0002512
FACILITY_NAME
GSG GAS & MART
STREET_NUMBER
701
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734311
CURRENT_STATUS
01
SITE_LOCATION
701 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br />SAN JOAHIN <br />1 --COUNTY <br />�`+^` Gre�otn�<c mows <br />hrr�. <br />Is <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />GSG GAS & MART <br />Facility Phone: <br />(209) 467-0305 <br />Date: <br />June 06, 2018 <br />Facility Address: <br />701 E DR MARTIN LUTHER KING JR BLVD, STOCKTON, CA 95206 <br />CERS to: <br />10180955 <br />Inspection Contact: <br />Raj Singh <br />Title: <br />Manager <br />Phone: <br />(209) 467-0305 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For: <br />❑x Inspection ❑x Photos ❑ Samples <br />Consent Given By: <br />Raj Singh. Manager <br />Service Technician Onsite: Exp. Date: <br />Ed Stearns 11/09/2018 <br />Designated Operator: Exp. Date: <br />Alex Jabbari 10/03/2018 <br />Service Technician Manufacturer's Training: <br />VR, 08/09/19; VMI, 06/20/19 <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />File Review <br />101 <br />HSC 25284 <br />Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees <br />o V o R o COS <br />102 <br />HSC 25284(a)(3)(A)/(B) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />o V o R o COS <br />103 <br />HSC 25292.2, 25299.30 <br />Current financial responsibility documents not submitted <br />o V o R in COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />o V o R o COS <br />105 <br />CCR 2632(d)(1), <br />2634(d) <br />Failed to have an approved UST monitoring plan <br />o V o R o COS <br />106 <br />CCR 2632(d)(2), <br />2634(e) <br />Failed to have an approved UST response plan <br />o V o R o COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V ■ R o COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />o V o R o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />o V o R o COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />o V o R o COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />o V o R o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />o V o R o COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />o V o R o COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />D V o R o COS <br />115 <br />CCR 2715(a) <br />Failed to submit to EHD notification of designated operator identification or change w/in 30 days <br />o V o R o COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />o V o R o COS <br />117 <br />CCR 2663(h) <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />o V o R o COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />o V o R o COS <br />119 <br />HSC 25299(a)(8), <br />25299(b)(7) <br />Documents were falsified or misrepresented <br />o V o R o COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V o R o COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />o V o R o COS <br />122 <br />CCR 26310) <br />Failure to submit and maintain UST system component statement of compatibility for substance stared <br />EV o R ❑ COS <br />On Site Records <br />201 <br />CCR 2712(b) <br />Failure to maintain monitoring, maintenance, and fallow up action records <br />■ V ❑ R ❑ COS <br />FA0002512 PR0231059 SCO01 06/06/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 1 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.