Laserfiche WebLink
LEAK 1°1I N At-JNLl L 0% <br />0 <br />PERIODIC: TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELA': 3 MIN <br />PUMP THRESHOLD 10.00% <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />JAN 29, 2009 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />L 1:DISP. 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 2:DISP. 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 3:DISP. 5-6 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 4:DISP. 7-8 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 5:87 STP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 6:91 STP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 7:SPLIT ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />OUTPUT RELAY SETUP <br />R 1:87 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 1:FUEL ALARM <br />L 2:FUEL ALARM <br />L 3:FUEL ALARM <br />i L 4:FUEL ALARM <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM <br />L 1:SENSOR OUT ALARM <br />L 2:SENSOR OUT ALARM <br />L 3:SENSOR OUT ALARM <br />L 4:SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />L 6:SENSOR OUT ALARM <br />L 1:SHORT ALARM <br />L 2:SHORT ALARM <br />L 3:SHORT ALARM <br />L 4:SHORT ALARM <br />L 5:SHORT ALARM <br />L 6:SHORT ALARM <br />R 2:91 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />.L 1:FUEL ALARM <br />L 2 : F"UEL ALARM <br />L 3:FUEL ALARM <br />L 4:FUEL ALARM <br />L 5:FUEL F\.LARM <br />L 6:FUEL ALARM <br />L 1:SENSOR OUT ALARM <br />L 2:SENSOR OUT ALARM <br />L 3:SENSOR OUT ALARM <br />L 4:SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />L 6:SENSOR OUT ALARM <br />L 1:SHORT ALARM <br />L 2:SHORT ALARM <br />L 3:SHORT ALARM <br />L 4:SHORT ALARM <br />L 5:SHORT ALARM <br />L 6:SHORT ALARM <br />SMARTSENSOR SETUP <br />s 1:VEEDER-ROOT POLISHER <br />CATEGORY VAPOR VALVE <br />s 2:PRESURE SEN. <br />CATEGORY VAPOR PRESSURE <br />s 8:AMTP <br />CATEGORY ATM P SENSOR <br />PMC SETUP <br />PMC VERSION: 01.02 <br />VAPOR PROCESSOR TYPE <br />VEEDER-ROOT POLISHER <br />ANALYSIS TIMES <br />TIME: 11:59 PM <br />DELAY MINUTES: <br />