My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
701
>
2300 - Underground Storage Tank Program
>
PR0231059
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 4:26:58 PM
Creation date
11/16/2018 11:31:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231059
PE
2361
FACILITY_ID
FA0002512
FACILITY_NAME
GSG GAS & MART
STREET_NUMBER
701
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734311
CURRENT_STATUS
01
SITE_LOCATION
701 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />GSG GAS & MART <br />701 E DR MARTIN LUTHER KING JR BLVD, <br />June 26, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />104 <br />CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />UST Facility Operating Permit Application is lacking Board of Equalization (BOE) Maintenance Fee Account <br />Numbers or BOE number is incorrect. BOE number 44043892 shows as closed on 06/12/2016 Immediately log into <br />CERS, update the required information, and submit for review by the EHD. <br />UST Tank Information forms for both tanks is not current in CERS. The striker plate was selected as no, the tank <br />installation date was listed as 4/30/1998, records indicate install date was 03/26/1998, the owner operator <br />agreement is indicated as stored at facility. Any change of information must be updated in CERS within 30 days of <br />the changes. Immediately log into CERS, update the required information, and submit for review by the EHD. <br />This was corrected on site. <br />This is a Class II violation. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br />where monitoring will be performed. Current plan is lacking the location of the mechanical line leak detectors. <br />Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload <br />a copy of the UST Monitoring Site Plan. <br />This was corrected on site. <br />This is a minor violation. <br />121 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on June 20, 2016 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by July 20 2016. This <br />information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br />inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br />actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br />corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br />This is a Class II violation. <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the secondary containment on the <br />monthly designated operator monthly inspection report. The DO noted testting was done on 07/30/2015 when <br />testing was actually conducted on 06/30/2015. During the monthly inspection, the designated operator shall check <br />that all required testing and maintenance for the UST system have been completed and document the dates they <br />were done. Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. <br />This is a repeat violation, Class II. <br />EHD 23-01 Rev. 09/22/16 <br />Page 4 of 5 <br />FA0002512 PR0231059 SCO01 06/26/2017 <br />Underground Storage Tank Program OIR <br />