Laserfiche WebLink
UNDAGROUND STORAGE TAR SYSTEM <br /> DESIGNATED UST OPERATOR MONTHLY INSPECTION REPORT <br /> Facility Name: City of Lodi Inspection Date: August 22, 2008 <br /> Facility Address: 1331 S. Ham Lane City: Lodi <br /> Name of Designated UST Operator Conducting Inspection: Dennis Callahan <br /> International Code Council Certification No.: 1004653-UC Expiration Date: 12/20/2008 <br /> Signature: Phone: (209) 333-6800 ext.2690 <br /> NIA=Not A plicable <br /> Item MONITORING PANEL/ALARM HISTORY Yes No N/A <br /> 1. Is the monitoring system powered on and in proper operating mode? M ❑ ❑ <br /> 2. Is the monitoring system not currently showing any leak alarms? M ❑ <br /> 3. Is the Alarm History Report/log for the previous month available,and has it been reviewed by the M ❑ ❑ <br /> Designated UST Operator? (Attach a copy of the alarm history report/log to this inspection form.) <br /> 4. Has each alarm for the previous month been responded to appropriately? tY- J✓ M ❑ ❑ <br /> UST SYSTEM INSPECTION <br /> 5. Are tank-top containment sumps free of water,debris,and hazardous substance? Note:If the answer to Item 4 was"Yes,"skip <br /> to Item 0. Sumps where till alarm has occrtrrul in the post month mast he inspected it a qualified service technician has not responded to, and <br /> property addressed,the cause of the alarm.Documentation vert ing appropriate service should be attached to this report. <br /> Yes I No Yes No <br /> Sump Location: SAV Fuel Island ® 10 Sump Location: N/E Fuel Island M ❑ <br /> Sump Location:N/W Fuel Island ® ❑ Sump Location: S/E Shop M ❑ <br /> 6. Are spill buckets(containment structures)free of water,debris,and hazardous substance? <br /> Yes No N/A Yes No N/A <br /> Tank 1 ID— 10,000 Unleaded ® ❑ ❑ Tank 4 ID—Waste Oil ❑ ❑ M <br /> Tank 2 ID— 2,000 Unleaded M ❑ ❑ Tank 5 ID— ❑ ❑ = <br /> Tank 3 ID— 5,000 Diesel M I ❑ 1 ❑ Tank 6 ID— ❑ ❑ ❑_ <br /> 7. Are under-dispenser containment areas free of water,debris,and hazardous substance? <br /> Yes No N/A I Yes No N/A <br /> Dispenser— 1/2 Multi-product ❑ Dispenser— ❑ <br /> Dispenser— ❑ ❑ ❑ Dispenser— ❑ ❑ ❑ <br /> Dispenser— ❑ ❑ ❑ I Dispenser— ❑ ❑ ❑ <br /> Dispenser— ❑ ❑ I ❑ I Dispenser— ❑ ❑ <br /> 8. Leak detection is properly located within under-dispenser containment. <br /> YesjNoN/A Yes No N/A <br /> Dispenser— 1/2 Multi-product Dispenser— ❑ ❑ ❑Dispenser— ❑ Dispenser— ❑ ❑ ❑ <br /> Dispenser— ❑ Dispenser— ❑ ❑Dispenser— Dispenser— ❑ ❑ <br /> PAPERWORK INSPECTION Yes No N/A Date Done <br /> 9. Monitoring System Certification was completed within the past 12 months? M ❑ 1 El 9/27/2007 <br /> 10. Line Leak Detectors were tested/certified within the past 12 months? M ❑ ❑ 9/27/2007 <br /> 11. Spill bucket(containment structure)testing completed within the past 12 months? ® ❑ ❑ 9/27/2007 <br /> 12_ Line tightness testing completed within the required time frame? ® ❑ ❑ 2/13/2007 <br /> 13. Secondary containment tests completed within the required time frame? V 10/5/2007 c :eye <br /> 14. Enhanced Leak Detection completed within the required time frame? ❑ ❑ ® tt os.- <br /> 15. <br /> 5"15. Other re uired testing/maintenance was completed within required time frame? (List tesi/maintenance items below.) <br /> Describe Test/Maintenance: Drop Tube Integrity Test-every 3 yrs ® ❑ 11 10/31/2005 <br /> Describe Test/Maintenance: Static Torque& Rotation Test-every 3 yrs ® I ❑ 10 1 10/31/2005 <br /> FACILITY EMPLOYEE TRAINING Yes No N/A <br /> 16. Have all facility employees received the required on-the-job training within the past year? M ❑ ❑ <br /> 17. Have all facility employees hired within the past 30 days received the required on-the-job training.? Ell ❑ I ❑ <br /> Note: Explain any"No"answers in the"Comments"section on the following page.Those issues require corrective action from <br /> the UST owner/operator. <br /> LIN-057-1/2 www.unidoes.org 9/26/05 <br />