SCS ENGINEERS- <br /> Health and Safety Considerations <br /> Work on or near landfill sites warrants special precautions to mitigate against potential — <br /> combustible gas hazards or worker exposure to the trace constituents of LFG. <br /> Appendix A of this document provides a H&S Plan for the well installation activities. <br /> The H&S plan describes potential hazards and outlines site-specific protection, <br /> monitoring and recordkeeping standards. SCS Engineers and the drilling subcontractor <br /> will be responsible for implementing these H&S provisions. — <br /> 5. PROPOSED LFG MONITORING PARAMETERS AND FREQUENCY <br /> Subsurface Gas Monitoring <br /> Landfill gas monitoring at the perimeter migration wells will be performed on a quarterly _ <br /> basis using field instruments. Parameters to be tested at each well/probe include: <br /> • Subsurface pressure. Monitoring shall be performed using a gauge (or <br /> combination of gauges) with a suggested range of 0 to 10 inches water <br /> column. <br /> • Methane concentrations. Monitoring shall be performed using a combustible <br /> gas indicator(s) with a dual range of 0-100% LEL and 0-100% v/v. <br /> Results will be recorded on field data sheets. Field personnel will record the above <br /> information as well as test date, time, weather conditions, and barometric pressure. <br /> If methane concentrations above the LEL are detected at any well location, the data will <br /> be reviewed for accuracy, and an evaluation will be made to rule out possible <br /> interferences. Such interferences could include the presence of subsurface liquids, or <br /> previously unidentified combustible gas sources. — <br /> Follow-up field testing will be performed if necessary. Depending on field results, <br /> confirmatory samples will be obtained for lab analyses. The sample(s) will be analyzed <br /> for the major components of LFG (methane, oxygen, nitrogen and carbon dioxide, with <br /> a detection limit of 0.1 % v/v). Should the sample results confirm the field readings, the <br /> County will notify the LEA and the CIWMB within 5 days of detection. _ <br /> If after two consecutive quarterly sampling events the results of monitoring at any <br /> single well or probe indicate methane concentrations above the LEL, a confirmatory <br /> sample will be obtained for analysis of trace gas constituents. Analyses will be as <br /> specified for the Air SWAT "Attachment 1 " compounds, with disposal site detection <br /> limits (refer to Table 2). <br /> Based on test results, the County will confer with the LEA regarding the need for <br /> remedial action (refer to Section 7)• <br /> 11 - <br />