My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
REMOVAL 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2019 4:26:37 PM
Creation date
12/6/2018 9:03:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2011
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY ENVIRONMENTAL HEAL H DEPARTMENT <br /> UST WORKSHEET FOR SITE CLOSURE EVALUATION <br /> I. FACILITY/TANK INFORMATION DATE: 1 6-15-11 <br /> SITE/FACILITY NAME: City of Lodi Municipal Service Center SR0062153 STATUS CODE: <br /> ADDRESS: 1331 S. Ham Lane Lodi,CA 95240 CITY: Lodi,CA <br /> FA# 3961 PR# 231332 TANK# 0133204 <br /> TANK SIZE: 2,000 FUEL TYPE: Used oil <br /> II. GENERAL SITE HISTORY <br /> Is Permit Current? X Yes ❑ No Documented Soil/GW Contamination?""* ❑ Yes No <br /> Number of Tanks at Facility 4 Age of Tanks(if available) Type of Tank xSteel ❑Fiberglass ❑Single <br /> ❑Dual <br /> III. TANK HISTORY <br /> Was Tank Tested? ❑ Yes ❑ No Failed Testing? ❑ Yes ❑No If Yes, Provide Dates: <br /> Was Tank System Repaired? ❑ Yes ❑ No If Yes,Describe Repair: <br /> Was Repair Done Under Permit? ❑Yes ❑ No Were Soil Samples Analyzed? x Yes ❑No X BTEX X TPH-G X TPH-D X LEAD <br /> X EDB x OTHER:ox s,metals, PCB,8260B <br /> Type of Failure/Discharge: ❑ Catastrophic ❑Long-term Leak ❑ Overfill ❑Unknown x Other tank removal <br /> IV. REMOVAL HISTORY Attach File <br /> Soil Samples Received? X Yes ❑ No Seasonal High Depth to GW —AME ft bgs Year/Reference Jvae 10 <br /> Onsite and/or Nearby Well(s)? ❑Yes x No <br /> L3 Irrigation: # Distance to Tank ft � Score 10 C Score 9 C <br /> ❑Domestic:# Distance to Tank ft 0 points if 0 points if 0 Score 5 points if <br /> ❑Public: # Distance to Tank ft R condition is R condition is R condition is met <br /> V. SITE FEATURE–LEACHING POTENTIAL ANALYSIS E met E met E <br /> Minimum Depth to Groundwater from Soil Sample Depth(feet)* >100 51 –100 5 25-501 <br /> Fractures in Subsurface(applies to foothill or mountain areas) 10 None <br /> Average Annual Precipitation(14 inches for SJC area) -------- <10 9 10-25 ------- 26-402 <br /> Man-Made Conduits which Increase Vertical Migration None 9 Unknown Present <br /> i.e.septic sstems,water wells, ponds) <br /> Unique Site Features: Recharge Area,Coarse Soil(coarse sands, 10 None At Least One More Than One <br /> gravels),nearby wells <br /> Column Totals Total Points 20 + 18 + 5 =43 <br /> Sample Results for BTEX: Range of Total Points 49 Points or More 41 –48 Points 40 Points or Less <br /> ND(detection limit 5 ug/kg) Maximum Allowable BTEX BT E X B T E X N/A3 <br /> Levels m 1.0 50 50 50 0.3 0.3 1.0 1.0 <br /> Sample Results for TPH: Maximum Gasoline 1,000 100 10 <br /> ND(detection limit 10 Allowable TPH <br /> Levels m Diesel 10,000 1,000 100 <br /> Footnotes: ***If documented soil and/or groundwater contamination is present,do not complete leaching potential analysis(i.e.site is already on the contamination list). <br /> 1 If depth is>5 feet and<25 feet,score 0 points. If depth is-5 feet,do not use table. 2 If precipitation is>40 inches,score 0 points. <br /> 3 Levels for BTEX are not applicable at a concentration of 10 ppm for TPH—Gasoline or 100 ppm for TPH-Diesel. <br /> VI. STAFF RECOMMENDATION/REFERRAL]REVIEW <br /> 1. Are BTEX or TPH Concentrations>Allowable Levels? LJYe x N 2. If No, Is Site Closure Recommended x Ye L3 No <br /> Completed By: Aris Cacapit Date Referred to Site Mitigation Unit for Final Actiont 6-15-11 <br /> Reviewed By: W� Concur with Staff Recommendation IlKes ❑ No <br /> Date Closure Letter Mailed tAII Cases are Referred to Site Mitigation for Final Action <br /> *Subtract soil sample depth from groundwater depth to determine distance be sample depth and groundwater <br /> EH 23-0080(Rev6/4/2007) <br />
The URL can be used to link to this page
Your browser does not support the video tag.