Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LODI MUNI SERVICE CENTER 1 1331 S Ham Ln Lodi September 25 2014 <br /> UST System Observations <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R ❑COS <br /> 328 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I.CLASS II,or MINOR-Notice to ComDlv) <br /> Item# Remarks <br /> 113 Failed to submit monitoring system certification test report within 30 days. A monitoring system certification, leak <br /> detector testing, and spill container testing were performed on 9-27-13 and a test report has not been submitted to the <br /> EHD. A copy of the test report must be submitted within 30 days of the test. Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload a copy of the test report as a <br /> miscellaneous State-Required Document in the Underground Storage Tank section. This is a minor violation. <br /> 314 Primary containment not tight(pre-Jul 2003). Diesel meter inside dispenser# 1/2 is leaking diesel and accumulating on <br /> the rim of the diesel fuel filter, indicating a leak in the primary. All primary containment for the UST system must be tight. <br /> Immediately have a properly licensed, trained, and certified contractor repair or replace the failed component under pern <br /> and inspection of the EHD. This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 10-25-14. <br /> Consent to perform the inspection, take photos and colleci samples was given by Randy Laney . This facility's <br /> Rec ' ed by(initial): Inspector: Phone: Date: <br /> ARIS VELOSO, Senior REHS ah � (209) 468-3453 09/25/2014 <br /> Page 3 of 4 <br />