Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />1 <br />Facility Address: <br />Date: <br />LODI MUNI SERVICE CENTER <br />1331 S HAM LN LODI <br />September 17 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />110 <br />CCR 2637(e) Failed to submit secondary containment test report within 30 days. <br />Secondary containment testing was performed on October 24, 2017 and a test report was submitted on December 13, <br />2017, one month late. A copy of the test report must be submitted within 30 days of the tests. Take all necessary <br />precautions to ensure testing and submittal of test reports are performed in a timely manner. <br />This is a minor violation. <br />115 <br />CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change w/in 30 days. <br />A new designated operator, Nicholas Graham -Lewin was hired in May 2018 and notification was not provided to the <br />EHD within 30 days of the change. Any changes shall be reported to the EHD within 30 days. Immediately log into <br />the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload the notification <br />identifying all the designated operators for this facility. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />201 <br />CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br />Maintenance and monitoring records for the last three years were not found on site. -Secondary containment test <br />results for October 2017 were not found on site. <br />-Work orders were not available for the repair and retesting conducted on secondary containment systems after <br />failures during the October 2017 testing. <br />These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of all <br />monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br />observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br />monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br />reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br />site and submit copies to the EHD. <br />This is a repeat violation, Class II. <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the secondary containment testing on the <br />designated operator monthly inspection reports. <br />-The test date was listed as 10/9/17 on the November 2017 through May 2018 reports. <br />-The test date was listed as 10/9/14 on the June, July, and August 2018 test reports. <br />The testing was conducted on 10/24/17. <br />During the monthly inspection, the designated operator shall check that all required testing and maintenance for the <br />UST system have been completed and document the dates they were done. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. <br />This is a repeat violation, Class II. <br />FA0003961 PR0231332 SCO01 09/17/2018 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />