Laserfiche WebLink
SAN JOAQUIN <br /> Environmental Health Department <br /> CCU 1T <br /> Food Program Official Inspection Report <br /> Facility Name and Address: Bon Appetit Marketplace, 901 President Dr, STOCKTON 95211 <br /> #30 Food Storage/Display Properly Labeled <br /> OBSERVATIONS:Large food bins at dry storage lack lids. Other lids are broken. Provide new lids by 2 weeks. <br /> CALCODE DESCRIPTION:Food shall be stored in approved containers and labeled as to contents. Food shall be stored at least 6" <br /> above the floor on approved shelving. (114047, 114049, 114051, 114053, 114055, 114067(h), 114069(b)) <br /> #33 Nonfood Contact Surfaces Clean <br /> OBSERVATIONS:Some floor sinks are not clean.All sink shall be cleaned on a routine basis. Correct by 11/16/17 <br /> Drawers for utensils at main food prep line are not clean. Clean and maintain. <br /> Exterior of some equipment are greasy/dusty.Wipe/degrease daily. <br /> CALCODE DESCRIPTION:All nonfood contact surfaces of utensils and equipment shall be clean. (114115(c)) <br /> #35 Equipment/Utensils Approved and in Good Repair <br /> OBSERVATIONS:Walk in coolers wire racks and metal racks with wheels have mold (lair/catering, meat/dairy, produce) <br /> All shall be cleaned by 2 weeks. <br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair. (114175).All utensils and equipment <br /> shall be approved,installed properly,and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, <br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182) <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:Some hood filters are greasy. Other filters are off track. Clean all filters and make sure they stay in <br /> place. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft, or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored,served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:The hand sink at mexican prep lack proper cold water flow. Increase flow by 1 week. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> FA0019096 PR0528235 SCO01 11/14/2017 <br /> EHD 16-23 Rev.06/30/15 Page 2 of 4 Food Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />