My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231464
>
COMPLIANCE INFO 2004 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2019 11:58:25 AM
Creation date
12/13/2018 3:43:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2012
RECORD_ID
PR0231464
PE
2361
FACILITY_ID
FA0000914
FACILITY_NAME
TIGER EXPRESS STORES
STREET_NUMBER
1399
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1399 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
456
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of 5 <br />OFFICIAL INSPECTION REPORT <br />Date: 06/28/12 <br />Facility Address: 1399 Yosemite Avenue, Manteca <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />201. Maintenance records were not found on site. These records shall be kept on site for at least 3 <br />years. Immediately locate and maintain the maintenance records on site and submit copies to the EHD <br />within 30 days of receiving this report. <br />205. All the designated operator monthly inspection reports were not found on site. Designated <br />operator monthly inspection reports for the previous twelve months shall be retained on site. Locate and <br />ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br />maintained on site. Submit copies to the EHD within 30 days of receiving this report. <br />206. The designated operator employee training for Ted Shackleford was not performed. The <br />designated operator shall train facility employees for which he or she is responsible in the proper <br />operation and maintenance of the UST system once every 12 months. The training shall include, but is <br />not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and <br />submit a copy of the training records to the EHD within 30 days of receiving this report. <br />311. The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. The leak detector was replaced and retested <br />during the inspection. Obtain a permit from the EHD for this work within one business day. The <br />technician Jessi Wadkins replaced the leak detector 99LD2000, SR# 12011012, retested and passed. <br />313. The 91 direct -bury spill container failed when tested. All spill containers shall have a minimum <br />capacity of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. <br />Immediately discontinue deposition of petroleum into this tank until the component is repaired or <br />replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EHD. <br />If the spill container can't be replaced immediately, there is a possibility that the 91 UST system may be <br />red tagged to prevent fuel inputs. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Muniappa Naidu (209) 468-3439 <br />Received By:Title: <br />vw,� � �a'"a` �°� <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.