My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231464
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 10:49:09 AM
Creation date
12/14/2018 3:38:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231464
PE
2361
FACILITY_ID
FA0000914
FACILITY_NAME
TIGER EXPRESS STORES
STREET_NUMBER
1399
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1399 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RFCEIV <br /> UNIMID PROGPAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK A-Ul n 4 2013 <br /> MONITORING PLAN-(Page I of 2) <br /> TYPE OF ACTION ❑1,NEW PLAN ❑ 2.CHANGE OF INFORMATION 490-1 <br /> PLAN TYPE [f1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. HEALTH P1k:PARTMENT <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM <br /> I. FACILITY INFO"IATION <br /> FACILITY 10#(Agency Use Only) - ) <br /> BUSINESS NAME(Same as FACILITY NAME) r)4,N --P r 3. <br /> 13USINESS SITE ADDRESS r ct 6- 103 CITY tJ f �j3 I04 <br /> 1I:EQUIPMENT TESTING AND PREVENTIVE:MAINTENANCE. <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors.probes,line leak detectors,etc)must be perfom3ed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR 2632 2634 2638 264I <br /> MONITORING EQUIPMENT IS SERVICED 1�.ANNUALLY ❑ 99,OTHER(Specify): 49904b <br /> XIX.MONITORING LOCATIONS, <br /> ❑1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. ❑2.SITE PIAT PLANIMAP PREVIOUSLY SUBMITTED, (23 CCR§2632, <br /> 2634)490.4 <br /> IV.TANK MONITORING.IS PERFORMED USING.THE FOLLOWING.MXTH0D(S); <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490.5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: [j a.DRY []b.LIQUID FILLED ❑ c.PRESSURIZED El d.UNDER VACUUM 490 c <br /> PANEL MANUFACTURER: .)PeaaY /Coo} 490-7. MODEL#; TO 490-5 <br /> LEAK SENSOR MANUFACTURER: I ) )) 49-79. MODEL N(S)- v71g -J O 1 A,56 49110 <br /> El2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL_TA1`JM (23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER 4p0-12' MODEL#: 49113 <br /> IN-TANK PROBE MANUFACTURER: 491-14' MODEL#(S): 49115 <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILYNIGHTLY ❑ c,WEEKLY 49116 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 49117 <br /> PROGRAMMED TESTS: Cl a.6.1 g.p.h. ❑ b.0,2 p,h. ❑ c.OTHER Speci : 49119 <br /> g. ( fY) 490-19 <br /> ❑ 3-MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646-1)_ 490-20 <br /> ❑ '4,WEEKLY MANUAL TANK GAUGING(MIG)(23 CCR§2645). TESTING PERIOD: ❑ a,36 HOURS ❑ b.60 HOURS 490-22 <br /> 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490-23 <br /> TEST FREQUENCY: [3 a ANNUALLY [Ib.BIENNIALLY [I c,OTHER(Speciff): 490-as <br /> El99.OTHER(Specify): 490-2e <br /> ago-z7 <br /> V;PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S).(Check all that apply)_ <br /> CONTINUOUS MONITORING OF PIPE/PIPING SUMPS)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 490-26 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT 1S:gra.DRY ❑b.LIQUID FILLED ❑c,FRESSURIZED ❑d.UNDER VACUUM 490.29 <br /> PANEL MANUFACTURER: t 490.30 MODEL#: T-1- S 490.31 <br /> LEAK SENSOR MANUFACTURER / IF I 490 32 MODEL 0(5): fl 490.33 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ❑a.YES ❑b.NO 490 34 <br /> FAILURFlD1SCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49135 <br /> ❑ 2,MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED 23 CCR 4Z630 490.36 <br /> MLLD MANUFACTURERS: 490-37 MODEL.#(S): Ft i V KI71 s <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)TI4AT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490-39 <br /> ELLD MANUFACTURER(S) T AIN*. MODEL w): 49041 <br /> PROGRAMMED IN LINE LEAK TEST. C31.MINIMUM MONTHLY 0.2 S.p.h, [J2.MINIMUM ANNUAL 0.1 g.p.tL 490-42 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. Cl a.YES ❑b.NO 49043 <br /> ELLD FAILURF/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN, ❑a.YES ❑b.NO 49144 <br /> ❑ 4.PIPE INTEGRITY TESTING 490.45 <br /> TEST FRE UENCX 0 a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c,OTHER(Specify) 490.46 49047 <br /> ❑ <br /> S.VISUAL PIPE MONITORING. 49"5 <br /> FREQUENCY ❑ a DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED' 4909 <br /> •Allmod for u"hokft Of unbOed tmeratncY gcnamtDf fuej Piling 012 Per HSC§25291-50-M <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA[23 CCR§2636(a)(3)1. 490,50 <br /> El 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490-31 49132 <br /> ❑ 99.OTHER(Specify) 490-$3 <br /> UPCFUST-D(IV2007)1/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.