Laserfiche WebLink
RS-232 END OF MESSAGE <br /> FAST N EBY 16 DISABLED <br /> 1399 E.YOSEMITE <br /> MANTECA CA.95336 AUTO DIAL ALARM SETUP <br /> 205-823-3460 COMMUNICATIONS SETUP — — — — — — — - — — — — <br /> JUN 6. 2017 9:41 — — — — — — — — — — — — <br /> PORT SETTINGS: <br /> SYSTEM STATUS REPORT COMM BOARD 1 (RS-232) <br /> ALL FUNCTIONS NORMAL PARITY <br /> RATE 9600 <br /> PARITY NONE <br /> STOP BIT 1 STOP d <br /> DATA LENGTH: 8 DATA <br /> RS-232 SECURITY IN—TANK SETUP <br /> CODE : DISABLED — — — — — — — — — — — — <br /> COMM BOARD 2 (S—SAT ) T 1 :REGULAR 87 <br /> BAUD RATE 1200 PRODUCT CODE 1 <br /> PARITY : ODD THERMAL COEFF : .000700 <br /> SYSTEM SETUP STOP BIT 1 STOP TANK DIAMETER 92.00 <br /> — — — __ — — — — — DATA LENGTH: 7 DATA TANK PROFILE 4 PTS <br /> JUN 6. 2017 9:41 RS-232 SECURITY FULL VOL 9728 <br /> CODE : DISABLED 69.0 INCH VOL 7910 <br /> DTR NORMAL STATE: HIGH 46.0 INCH VOL 4864 <br /> 23.0 INCH VOL 1818 <br /> SYSTEM UNITS AUTO TRANSMIT SETTINGS: <br /> U.S. <br /> SYS'T'EM LANGUAGE AUTO LEAK ALARM LIMIT FLOAT SIZE: 4.0 IN. <br /> ENGLISH DISABLED <br /> SYSTEM DATE/TIME FORMAT WATER WARNING <br /> IKON DD YYY'Y HH:1'111:SS AUTO HIGH WATER LIMIT 1 .0 <br /> DISABLED HIGH WATER LIMIT: 2.0 <br /> FAST N EBY 16 AUTO OVERFILL LIMIT MAX OR LABEL VOL: 9728 <br /> 1399 E.YOSEMITE DISABLED OVERFILL LIMIT 90%. <br /> MANTECA CA.95336 AUTO LOW PRODUCT <br /> 8755 <br /> 209--823-3460 DISABLED HIGH PRODUCT 95% <br /> AUTO THEFT LIMIT <br /> DISABLED 9241 <br /> SHIFT TIME 1 DISABLED DELIVER;' LIMIT 1064 <br /> SHIFT TIME 2 DISABLED AUTO DELIVERY START <br /> SHIFT TIME 3 DISABLED DISABLED 972 <br /> SHIFT TIME 4 DISABLED AUTO DELIVERY END LOW PRODUCT 531 <br /> DISABLED LEAK ALARM LIMIT: 99 <br /> TANK PER T.:I' I••l CDVD WRN AUTO EXTERNAL INPUT ON SUDDEN LOSS LIMIT: 99 <br /> D I SABLEL- DISABLED TANK TILT 1 .85 <br /> TANK ANH • ;"I riL_. I', WRN AUTO EXTERNAL INPUT OFF PROBE OFFSET 0.00 <br /> DISABLED DISABLED <br /> AUTO SENSOR FUEL ALARM <br /> LINE RE—ENABLE METHOD DISABLED MANIFOLDEIi TANKS <br /> AUTO SENSOR WATER ALARM <br /> PASS LINE TEST DISABLED Tat: NONE <br /> LINE PER TST NEEDED 1AIRN AUTO SENSOR OUT ALARM <br /> DISABLED DISABLED LEAK MIN PERIODIC: 0% <br /> LINE ANN TST NEEDED WRN 0 <br /> DISABLED <br /> LEAS: MIN ANNUAL 0% <br /> PRINT TC VOLUMES 0 <br /> ENABLED RECEIVER SETUP: <br /> TEMP COMPENSATION NONE PERIODIC TEST TYPE <br /> VALUE (DEG F ) : 60.0 STANDARD <br /> STICK HEIGHT OFFSET <br /> DISABLED ANNUAL TEST FAIL <br /> ALARM DISABLED <br /> H—PROTOCOL DATA FORMAT <br /> HEIGHT PERIODIC TEST FAIL <br /> DAYLIGHT SAVING TIME ALARM DISABLED <br /> DISABLED <br /> RE—DIRECT LOCAL PRINTOUT GROSS TEST FAIL <br /> DISABLED ALARM DbSABLED <br /> EURO PROTOCOL PREFIX AUTO DIAL TIME SETUP: AN14 TEST AVERAGING: OFF <br /> S PER TEST AVERAGING: OFF <br /> NONE TANK TEST NOTIF`!: . OFF <br /> TNK TST SIPHON BREAKOFF <br /> DELIVERY DELAY 3 MIN <br /> PUMP THRESHOLD 10.00% <br />