Laserfiche WebLink
SOATO OF TRUSTEES SAN JOAQUIN LOCAL HEALTH DISTRICT SERVING <br /> Jarnes Culbertson, Pre*. <br /> City of Lodi <br /> APatriciaE. V , Secy. City <br /> venue, P. O. Box 200nthonhonella Van Spronaen 1601 Et Hazelton A9 San Joaquin CountyClt <br /> Earl Pimy of EaCalon <br /> entel Stockton, Callfornla 95201 C it or Manteca <br /> Fern Bugbee <br /> Daniel L. Flores 209/466-6781 City of Ripon <br /> John 0. Mast, M.O. City of StocktonCity of Tracy <br /> William J. Wade Jopl Khanna, M.O., M.P.H., District Health Officer San Joaquin County <br /> Mary Anna Love San Joaquin County <br /> Facility Name FAA"*'S l � �— <br /> Address 1311 [ YQ <br /> Date of Inspection Inspector <br /> MONITORING ALTERNATIVE N7 <br /> Limited to underground storage tanks which have infrequent inputs and withdrawals and <br /> where the liquic: level in the tank can be measured to an accuracy of +5 gallons or less <br /> when the tank is half full . <br /> This monitoring alternative shall include: <br /> 1�Annual precision test on tank and piping. <br /> y Tank gauging performed as follows: <br /> ------Tank must be capable of being secured to prevent unauthorized inputs and <br /> withdrawals. <br /> `Tank must have no inputs or withdrawals for at least a 48 hour period <br /> (2 days) at the end of consecutive periods lasting up to 7 days. <br /> (For example: tank in use Monday through Friday, then locked <br /> over weekend) . <br /> Liquid level measurements are taken at the beginning and end of the <br /> monitoring period (lasting at least 48 hours). <br /> (For example: level measured and recorded Friday night before <br /> n / locking and again on Monday morning before opening. ) <br /> l/ If liquid level varies more than 1% of the tank volume or 5 gallons , which <br /> ever is less , between measurements , an unauthorized release shall be <br /> assumed to have occurred and shall be reported to the local agency within <br /> 24 hours , as per Article 5, Sect. 2652 of the regulations and further <br /> evaluations shall be performed to verify or disprove the variations. <br /> Implementation of the monitoring alternative requires that the following circled items be <br /> completed by the dates specified. <br /> i . J Precision test(s)( ) must be performed by3- and results submitted to this <br /> office within 30 days of the test. <br /> 'Tank gauging must be started immediately. (See instructions above). <br /> If the above compliance dates cannot be met, contact this office prior to the specified <br /> date. <br /> 4/86 UGT 3 <br />