My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 2012 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 2:41:11 PM
Creation date
12/21/2018 3:49:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2017
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
280
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.so.ov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility Trac 76 <br />Name: Y <br /># I <br />Facility <br />Address: 2420 West Grant Line Road, Tracy <br />Inspection <br />Date: May 22, 2013 <br />Facility <br />Contact: Jivtesh Gill <br />Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />Title: owner <br />File Review <br />EWe <br />1139 <br />Inspection <br />Type: XRoutine XMonitoring System <br />Certification I I Installation "Complaint -ID#: <br />_ Other: <br />(Authority HSC 25289) <br />�Gi, ' <br />'OWire1` Nf` <br />Consent for: �s(Inspection XSampling XPhotos <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 CCR 2638 (e) test notification not provided to the EHD at least 48 houm prior to conducting an installation, repair, <br />replacement, calibration, or certification L <br />Granted by: tl�'1� <br />Title: t `' G <br />Monitoring Veeder-Root TLS -350 <br />Panel: <br />Piping <br />System: <br />XPressurized Suction-Gravit y <br />Overfil <br />Prevention: <br />XMechanical SAudible/visual <br />UST <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />4 <br />120 HSC 25298(c) Permit to close UST system not obtained <br />On Site Records <br />5 <br />6 <br />CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'h years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 <br />-Product - <br />- - - ----- <br />-_87-octane - <br />203 <br />- - <br />- 91 -octane - <br />- - - - <br />- DSL- -`- <br />--------' <br />-- <br />------------ <br />Designated <br />Des <br />onana art y <br />ICC Exp. <br />0614/011 <br />Violations: XM1-Release Detection <br />_ M2 -Release Prevention i, M3 -Both <br />Operator: <br />Date: <br />On Site ServiceICC <br />T(JY( �Fjv )aP <br />Exp. <br />/^ Manufacturer's [// <br />r 60( <br />3 U(j� �01 <br />Technician: - <br />Date: <br />W,� Training: <br />VIOLATIONS <br /># I <br />C1 <br />C2 <br />M I <br />Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />File Review <br />101 HSC 25284 No permit to operate <br />102 HSC 25404.5 Annual operating fees not paid <br />103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test q 1Z <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 CCR 2638 (e) test notification not provided to the EHD at least 48 houm prior to conducting an installation, repair, <br />replacement, calibration, or certification L <br />110 HSC 25291 (1) Annual line leak detector test not performed (Mi) <br />111 HSC 25284.2 Annual spill containment testing not performed <br />112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 Permit to repair UST system not obtained <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) Permit to close UST system not obtained <br />On Site Records <br />201 <br />CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'h years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 <br />CCR 2712(1) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 <br />CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspector: Received By: Title: <br />Thuy Tran (209) 468-8257 C <br />17- <br />EHD <br />Z <br />EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.