Laserfiche WebLink
> 1 n <br /> SEP 2�3; <br /> Appendix VI <br /> MONITORING SYSTEM CERTIFICATION EWRONMENTAI HE/A) (-H <br /> For Use By All Jurisdictions Within the State of California pERMl!T/SFRvif q <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: TRACY 76 Bldg.No.: <br /> Site Address: 2420 W. GRANT LINE RD. City: TRACY zip: 95376 <br /> Facility Contact Person: Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: GILBARCO E M C Date of Testing/Servicing: 5/9/2017 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: 87 Tank Size: Tank ID: _ Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG 7 ❑ In-Tank Gauging Probe. Model: <br /> ® Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 2 0 5 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: 99 LD 2000 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIE Tank Size: Tank ID: 91 Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG 2 ® In-Tank Gauging Probe. Model: MAG 7 <br /> ® Annular Space or Vault Sensor. Model: 420 ® Annular Space or Vault Sensor. Model: SHARED W/DSL <br /> .® Piping Sump/Trench Sensor(s). Model: 205 ® Piping Sump/Trench Sensor(s). Model: 2 0 5 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: LD 2000 ® Mechanical Line Leak Detector. Model: LD 2000 <br /> '❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: I / 2 Dispenser ID: 3 / 4 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5 / 6 Dispenser ID: 7 / 8 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report 4 � <br /> Technician Name(print): ZANE NIMMO Signature: _y <br /> Certification No.: A28446 License No: 04--1'676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (2 6)744-0113 <br /> Testing Company Address: 416 2n1 STREET GALT,CA 95632 Date of Testing/Servicing: 5/9/2017 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br /> �C- <br /> � .. <br />