My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0006063
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1399
>
3500 - Local Oversight Program
>
PR0543988
>
ARCHIVED REPORTS XR0006063
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2018 11:05:57 AM
Creation date
12/28/2018 11:05:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006063
RECORD_ID
PR0543988
PE
3500
FACILITY_ID
FA0000914
FACILITY_NAME
TIGER EXPRESS STORES
STREET_NUMBER
1399
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1399 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The sampling equipment consists of a"Tedler bag(available The probe tip is then lowered Into the well and submerged in <br /> in 1 3,5 and 10 Inter sizes) a diaphragm pump and 1/4-mch- the groundwater An oscillating(beeping)tone indicates the <br /> diameter polyethylene tubing(apprommsitely 1 foot long) probe is in water The probe is slowly raised until either the <br /> oscillating tone mases or becomes a steadytone in either <br /> The sampling ports are brass connections fitted with a silicone case,this is the depth-to-water(DTW)indication and the DTW <br /> septa and threaded into a tapped hole in the system piping measurement is made accordingly The steady tone indicates <br /> The sampling procedure requires one end of the tubing be floating liquid hydrocarbons(FLH) In this case the probe m <br /> slipped over the sampling port and the other end over the slowly raised until the steady tone ceases This Is the depth-to- <br /> diaphragm pump to acquire an air-tight connection The product(DTP)indication and the DTP measurement is made <br /> sampling pump is purged for 1 minute with the e)tmcted vapor accordingly <br /> to be sampled Following purging the discharge of the pump <br /> is then diverted through a two-way valve into the"Tedlar"bag The process of lowering and raising the probe must be <br /> which should be filled to 314 of volume capacity Caution repeated several times to ensure accurate measurements The <br /> should betaken not to overfill the sampling bag The sample is DTW and DTP measurements are recorded on the Irquid4evel <br /> placed in a non-refrigerated dry cooler with sufficient packing to data sheet When FLH are indicated by the probe's response, <br /> eliminated damage during transport Cooling samples will a product bailer is lowered partmilythrough the FLH-water <br /> cause condensation of moisture within the sample thereby interface to confirm the FLH on the water surface and as <br /> distorting laboratory analysis further indication of the FLH thickoiess particularly in cases <br /> where the FLH layer is quite thin This measurement is <br /> For quality control purposes a duplicate vapor sample should recorded on the data sheet as"FLH thickness" <br /> be collected from each sampling port This sample is then put <br /> on hold at the laboratory pending initial analysis To ensure In order to avoid cross-contamination of wells during the liquid- <br /> quality control and minimize the potential for cross- level measurement process wells are measured in the order of <br /> contamination prior to and during sampling the diaphragm "clean"to"dirty'(where such information is available) in <br /> pump is thoroughly purged for approiamately 5 minutes with addition all measurement equipment is cleaned with solution <br /> nitrogen or clean air(i a compressed clean air) A"blanW and thoroughly rinsed with deconized water before use between <br /> sample of the discharged air is captured in a"Tedlar• bag at measurements in respective wells and at the completion of the <br /> the end of the purging procedure and may be analyzed to days use <br /> ensure the purging was effective <br /> To minimize the potential for cross-contemination between air <br /> samples the polyethyiene tubing if not sample dedicated is <br /> thoroughly cleaned and rinsed <br /> Vapor samples are subject to very limited holding times <br /> typically 48 hours Thus care must taken to avoid delays in <br /> • submittal of vapor samples to the laboratory In the evert the <br /> vapor samples cannot be submitted to the analytical laboratory <br /> on the same day they are collected they are to be temporarily <br /> stored in the dry non-refrigerated packed cooler until the very <br /> first opportunity for submittal veli within the required holding <br /> time taking into account the time needed for shipment to and <br /> receipt by the laboratory <br /> SOP-11 2 <br /> MEASURING LIQUID LEVELS USiNG <br /> WATER LEVEL METER OR INTERFACE <br /> PROSE <br /> Field equipment used for liquid-level gauging typically includes <br /> the measuring instrument(water-level meter or interface probe) <br /> and product bailer(s) The field iat also includes cleaning <br /> supplies(buckets solution spray bottles and deionized water) <br /> to be used in cleaning the equipment between wells <br /> Prior to measurement the instrument tip is lowered into the well <br /> until a touches bottom Using the previously established top-of- <br /> casing or top-of-box(i a wellhead vault)point the probe cord <br /> (or halyard)is marked and a measuring tape(graduated in <br /> hundredths of a foot)is used to determine the distance <br /> between the probe end and the marking on the cord This <br /> measurement is then recorded on the irquid-level data sheet as <br /> the"Measured Total Depth"of the well <br /> When necessary in using the interface probe to measure liquid <br /> levels the probe is first electrically grounded to either the metal <br /> stove pipe or another metal object nearby When no ground is <br /> available reproducible measurements can be obtained by <br /> clipping the ground lead to the handle of the interface probe <br /> case <br /> Page 2-SDP Operation&Maintenance <br />
The URL can be used to link to this page
Your browser does not support the video tag.