Laserfiche WebLink
CONQMONS FOR N-3536-1-1 Page. 2 <br /> 7. Initial compliance with VOC emission rate and control efficiency requirements shall be demonstrated by <br /> the results of the laboratory sample analysis. The results shall be submitted to the District within <br /> 0 days of the test. <br /> 8. Ongoing compliance with VOC emission rate and control efficiency requirements shall be demonstrated by <br /> sampling both the influent and effluent gas streams with an FID, PID, or other District-approved VOC <br /> detection device. <br /> 9. Sampling to demonstrate ongoing compliance shall be performed at least once per week. <br /> 10. The soil remediation system shall be maintained in proper operating condition at all times. <br /> 11. The carbon canisters removed from the system shall be sealed vapor-tight. <br /> 12 Neither the soil ventilation rate or the effluent gas flow rate shall exceed 160 scfm. <br /> 13. Either the overall VOC control efficiency shall not be less than 95%, or the total VOC emission rate <br /> shall not exceed 2 pounds in any one day. <br /> 14 The VOC concentration of the effluent gas from the soil remediation system served by carbon canisters <br /> shall not exceed 2.3 ppmv <br /> 15. Records of the cumulative running time and the measured influent and effluent VOC concentrations shall <br /> be maintained. <br /> Ib All records shall be retained for a minimum of 2 years, and shall be made available for District <br /> inspection upon request. <br /> 17 Operation of the soil remediation system shall not exceed 1 year without prior District approval. <br /> i <br />