Laserfiche WebLink
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> HALEY FLYING SERVICE INC 1 15971 S TRACY BLVD, TRACY January 07, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 609 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately contain procedures for reporting a discharge. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan does not provide information and procedures to <br /> enable a person to adequately report a discharge. The SPCC plan contains the incorrect 24 hour reporting phone <br /> number for the California Office of Emergency Services and does not list the name or contact information for the <br /> local CUPA, the San Joaquin County Environmental Health Department. If a response plan was not submitted to <br /> the Regional Administrator,this information must be included in the SPCC Plan. Immediately amend the SPCC <br /> Plan to include this information and submit a copy of the revision to the EHD. <br /> This is a minor violation. <br /> 612 CFR 112.7(c) Plan failed to include secondary containment, diversionary structures,or equip to prevent discharge. <br /> Appropriate secondary containment for the 1,000 gallon, 500 gallon and 125 gallon mobile refuelers is not <br /> discussed. Secondary containment for the 55 gallon drums throughout the facility which store new and used <br /> petroleum product is not discussed. A facility shall provide appropriate containment and/or diversionary structures <br /> or equipment to prevent a discharge. The entire containment system, including walls and floor, must be capable of <br /> containing oil and must be constructed so that any discharge from a primary containment system will not escape the <br /> containment system before cleanup occurs. Immediately amend the SPCC plan to discuss adequate secondary <br /> containment for all aboveground petroleum storage containers larger than 55 gallons. <br /> This is a Class II violation. <br /> 618 CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections,or integrity tests for three years. <br /> Copies of inspection and testing records for 2016 and 2017 were not found on site. Inspections and tests must be <br /> conducted in accordance with the written procedures developed in the Spill Prevention, Control, and <br /> Countermeasure(SPCC)Plan. Records of these inspections and tests must be signed by the appropriate <br /> supervisor or inspector and kept on site with the SPCC Plan for a period of three years. Immediately locate a copy <br /> of all inspection and testing records for the last three years, maintain them on site, and submit copies to the EHD or <br /> submit statements the will assure compliance with this regulation. <br /> This is a Class II violation. <br /> 628 CFR 112.7(a)(1), 112.70) Failure to include in the Plan discussion of conformance with Federal and State <br /> requirements. <br /> The SPCC plan did not include a discussion as described in this section. In addition to the minimal prevention <br /> standards listed under this section, include in your Plan a complete discussion of conformance with the applicable <br /> requirements and other effective discharge prevention and containment procedures listed in this part or any <br /> applicable more stringent State rules, regulations, and guidelines.Amend the SPCC plan to include a discussion on <br /> all applicable requirements. <br /> This is a minor violation. <br /> FA0009326 PR0515798 SCO01 01/07/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 7 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />