My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
121
>
2300 - Underground Storage Tank Program
>
PR0543446
>
INSTALL 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2019 10:52:47 AM
Creation date
1/16/2019 2:16:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2019
RECORD_ID
PR0543446
PE
2351
FACILITY_ID
FA0024656
FACILITY_NAME
7-ELEVEN #38153
STREET_NUMBER
121
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
121 S CENTER ST
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
631
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Guide Specifications for Xerxes Underground Petroleum Storage Tanks <br />Short form: <br />The contractor shall provide a double-wall or triple -wall fiberglass reinforced <br />plastic (FRP) UL -listed underground storage tank as shown on the drawings. <br />The tank size, fittings and accessories shall be as shown on the drawings. <br />The fiberglass tank shall be manufactured by Xerxes Corporation. <br />The tank shall be tested and installed according to the Xerxes Installation <br />Manual and Operating Guidelines for Fiberglass Underground Storage Tanks <br />in effect at time of installation. <br />Long form: <br />Part I: General <br />1.01 Quality Assurance <br />A. Acceptable Manufacturer: Xerxes Corporation <br />B. Governing Standards, as applicable: <br />1. Underwriters Laboratories (UL) Standard for Safety 1316 <br />Glass -Fiber -Reinforced Plastic Underground Storage Tanks for <br />Petroleum Products, Alcohols, and Alcohol -Gasoline Mixtures. <br />A UL label shall be attached to each tank. <br />2. National Fire Protection Association (NEPA) Standards: NFPA 30: <br />Flammable and Combustible Liquids Code, NFPA 30A: Code for <br />Motor Fuel Dispensing Facilities and Repair Garages, NFPA 31: <br />Standard for the Installation of Oil -Burning Equipment. <br />3. City of New York Department of Buildings M.E.A., #161-89-M. <br />4. American Concrete Institute (ACI) standard ACI 318-11, Building <br />Code Requirements for Structural Concrete. <br />C. Submittals <br />1. Contractor shall submit _ copies of shop drawings, <br />manufacturer's product brochures, and Installation Instructions. <br />Part II: Products <br />2.01 Double -Wall and Triple -Wall Fiberglass Reinforced Plastic (FRP) <br />Underground Storage Tanks: <br />A. Loading Conditions - Tank shall meet these design criteria: <br />1. Interstitial Pressure - The interstitial space of the tank shall <br />withstand a minimum 20 -prig pressure test. <br />2. Internal Load -Tank shall withstand a 5-psig air -pressure test <br />with a 5:1 safety factor. <br />3. Surface Loads -Tank shall withstand surface H-20 and HS -20 <br />axle loads when properly installed according to Xerxes' current <br />Installation Manual and Operating Guidelines. <br />4. External Hydrostatic Pressure - Tank shall be designed for 7' <br />of overburden over the top of the tank, the hole fully flooded <br />and a safety factor of 5:1 against general buckling. <br />B. Product Storage: <br />1. The primary compartment of double-wall and triple -wall tanks <br />shall be vented and operated at atmospheric pressure only. <br />2. Tank shall be capable of storing liquids with a specific gravity up <br />10 1.1. <br />3. Tank shall be capable of storing products identified in the <br />manufacturer's standard limited warranty in effect at the time <br />of purchase. <br />C. Materials: <br />1. The primary and secondary walls of the tank shall be <br />manufactured with 100% premium resin and glass -fiber <br />reinforcement. No sand or silica fillers shall be added to the <br />resin. <br />2. The interstitial space between the primary and secondary walls <br />shall be constructed with a glass reinforcement material such as <br />Parabeame, which provides a structural bond between the two <br />tank walls, while creating a defined interstice that allows for <br />free flow of liquid. <br />D. Tank Dimensions (Refer to Xerxes literature on gallonage): <br />1. Tank shall have nominal capacity of gallons. <br />2. Tank shall have nominal outside diameter of feet. <br />3. Tank shall have a nominal overall length of feet/inches. <br />2.02 Tank Monitoring System <br />10 <br />A. General <br />1. Tank shall be continuously monitored with the TRUCHEK® <br />hydrostatic leak monitoring system. <br />2. The continuous monitoring system shall include monitoring fluid <br />factory -installed in the interstitial space and within a fiberglass <br />tank -top mounted reservoir. <br />3. The monitoring system shall be recognized by the National <br />Work Group on Leak Detection Evaluations (NWGLDE) as <br />continuous leak detection and as a precision tank test. <br />4. The monitoring system shall be independently tested by a <br />qualified third party and verified to be capable of detecting <br />leaks as small as .05 gallons per hour when TRUCHEK <br />tank -tightness test procedures are followed. <br />B. Design <br />1. The continuous monitoring system shall be designed to detect <br />a leak in either the primary or secondary wall at all times, <br />regardless of the water -table conditions at the installation site. <br />2. The interstice of the tank shall be designed for a 5:1 safety factor <br />beyond normal hydrostatic operating pressure to ensure structural <br />integrity and to prevent false leak alarms. <br />2.03 Accessories <br />A. Tank Anchoring <br />1. Anchor straps shall be as supplied by tank manufacturer and <br />designed for a maximum load of 25,000 lbs. <br />2. Galvanized turnbuckles (two per anchor strap) shall be supplied <br />by the tank manufacturer. <br />3. Prefabricated concrete anchors shall be supplied by the tank <br />manufacturer, designed to the ACI 318-11 standard, <br />manufactured with 4,000 psi concrete, and shall have <br />adjustable anchor points. <br />B. Manways <br />1. The standard manway shall be flanged, 22" I.D. and complete <br />with UL -listed gaskets, bolts and covers as shown on tank <br />drawings. <br />C. Threaded Fittings <br />1. All threaded fittings shall be NPT half or full couplings, in 2", 4" <br />or 6" diameters. <br />2. Fittings shall be installed on the tank -top centerline or in the <br />cover of the manway as shown on the tank drawings. <br />D. Containment Collars & Sumps <br />1. The tank shall have factory -installed 42" -or 48" -diameter <br />containment collars as shown on the tank drawings. <br />2. Containment sumps in 42" -or 48" -diameter, provided by the <br />tank manufacturer and designed for mounting on the <br />containment collars, shall be supplied as shown on the tank <br />drawings. <br />3. Adhesive shall be provided by the tank manufacturer <br />with each containment collar and sump. <br />4. Containment collars and sumps shall be designed and supplied <br />as a containment system. Only sumps provided by the <br />manufacturer shall be allowed. <br />Part III: Testing and Installation <br />3.01 Testing <br />A. Testing - Tank shall be tested according to the Xerxes Installation Manual <br />and Operating Guidelines in effect at time of installation. <br />3.02 Installation <br />A. Installation - Tank shall be installed according to the Xerxes Installation <br />Manual and Operating Guidelines in effect at time of installation. <br />Part IV: Limited Warranty <br />4.01 Limited Warranty <br />A. Limited Warranty - Warranty shall be manufacturer's standard limited <br />warranty in effect at time of purchase. <br />
The URL can be used to link to this page
Your browser does not support the video tag.