San Joaquin County RECEIVED <br /> q tY <br /> Environmental Health Department AN <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> •'��LlpdRt'�p Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/eI10MR-ONMENTALHE&TH <br /> PEjWlT/SERt 'ES <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: 7-ELEVEN Date: 04/11/2019 <br /> Address: 121 S CENTER ST, STOCKTON 95202 <br /> Requestor: 7-ELEVEN, 7-ELEVEN#38153 Telephone: (925)353-7496 <br /> Program Element: 2303-UST/PIPING INSTALLATION Request#: SR0079171 <br /> Inspection Type: 131 -UST INSTALLATION INSPECTION <br /> Onsite Service Technician: Curtis Carpenter ICC Service Tech/Installer Exp. Date: 05/13/2020 <br /> Manufacturer training: Veeder Root, 12/04/20; OPW, 12/13/20 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site to: <br /> -Verify the dispenser footprints contained by the under dispenser containment sumps(UDCs).The fuel filters were observed <br /> to be outside the UDCs and any potential leaks from the fuel filters would not be drain directly into the UDCs. Ensure any <br /> potential leaks are contained by the UDCs.,6,B,Sv b <br /> -Verify overfill prevention prior to the first fuel deliveries.The measurements were verified to be at 95%capacity. The service <br /> technician on site verified the measurements to be accurate. ensure test results are submitted to EHD within 30 days from <br /> today's date. <br /> -Verify minimum 5 gallon capacity on the 87 product, 91 product and diesel product spill containers.All three spill container <br /> met the 5 gallon capacity, passed the 60 minute hydrostatic test. Proper drainage was verified on all three containers and <br /> found to be appropriate. <br /> -Verify monitoring system functionality prior to first delivery.All liquid sensors were tested and found to be functional. Smart <br /> sensor were for high liquid and found to be functional. S14-87 and 91 vent sensor had a wiring problem at the time of testing. <br /> The electrician on site,was able to rewire the sensor correctly. The sensor was retested after the rewiring with passing results. <br /> -Inaccurate AS Built plans have been submitted to EHD. 91 product line in DISP 3 is inacurate. Ensure correct as built plans <br /> are submitted to EHD. PefJ )eo i9TJ.9��f�lJ <br /> Communication was not tested during today's inspection. Per the foreman, Rafael Flores,all UST components,except for the <br /> tanks(hydrostatic),will be monitored under vacuum, for which fuel is necessary for the turbine to create vacuum.Therefore <br /> communication would not be able to be tested until after fuel delivery. <br /> The facility may received fuel once EHD has received and reviewed ELD test results.ffjfq��y,EO 4- SfW7-oeK C6W S <br /> This service request is NOT complete,the facility is not allowed to operate the UST system until approved by EHD. Please <br /> contact Elena Manzo to schedule future inspections. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Rafael Flores, Foreman <br /> EH Specialist: ZUNA BARKER Phone: (209)953-7311 <br /> SR0079171 SC131 04/11/2019 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />