Laserfiche WebLink
Epp GR Job# 19200023 <br /> �g44mjyg <br /> v�4p�an <br /> Emergency Shut-Off (ESO) Testing Results & Checklist <br /> Facility Information Contractor Information TEST Results <br /> Site#Arco 6080 Co Name. Gettler-Ryan 1 _ Date:1/22/2019 <br /> Address: Phone 925-551-7555 <br /> 85 E Louise Ave Lead Technician:David Rouse PASS <br /> CityfSt:Lathro CA Name. or <br /> eMaint.W.O.# 10212-744 Passport FAIL(Next Day Repair Required) <br /> Si nature <br /> The objective of this test Is to provide assurance that the when the E-Slop switch Is activated,all the fueling system circuits(turbines,and dispensers)are do-energized,and <br /> remain de-energized until they are re-set manually). The test procedures and guidelines shall be in accordance with the E-Stop Testing Process <br /> # The following Information Is to be completed. x T.S.W. <br /> r.. Mo WA <br /> SITE DATA <br /> Number of E-Stop switches 2 <br /> 2 Type of Switch? Push PuC Momentary]— Plain light!Toggle 1X1 Other <br /> (if Momentary type, locate and identify re-set button) In Eiect Room - '— <br /> 3 Type of Turbine Control Relay System(Electrical D,stribution Center) <br /> p Brown Box MR Power Solution n Other J0 Custom Fabricated <br /> 4 Type of Turbine Control Relays Make FE Petro Model MAG VFC <br /> 5 Type of Line Leak Detection: Mechanical ELD/CPT L_ij PLLD <br /> PERFORMANCE TEST <br /> e Does the E-Stop shutdown power to the DISPENSERS X <br /> 7 Does the E-Stop shutdown power to the TURBINES X <br /> 8 Is the 220 voltage to the turbine relay removed(either the line side or the motor side of the contacts or the coil)? X <br /> 9 Are the DISPENSER BREAKERS clearly identified;labeled? X <br /> to Are the TURBINE BREAKERS clearly identified/labe:ed? X <br /> 11 Are all the ESOs accessible and clearly identified I labeled? X <br /> t2 Did the ESO(s)function correctly(de-energized from either the line side or the motor side of the contacts or the coil)? X <br /> 12A If#12 is NO,briefly describe what was wrong <br /> 12B How was it corrected: <br /> 12C If repair or ESO functionality cannot be corrected same day(prior to leaving the site) The technician MUST notify the <br /> Site Manager of the problem,place an"Out of Sery ce"Tag on the ESO(s). and identify an alternate mean(i.e, locate <br /> circuit panel,clearly identify turbine and dispenser breakers for shut-off in the event of an emergency) <br /> 12D Elite Customer Solution Center has been contacted for the repair <br /> eMaint.W.O.Ticket# <br /> POSTTEST <br /> 11 Site's fueling system is fully operational x <br /> 12 All equipment secured and any access ports,lids,enclosures are closed x <br /> 13 All safety barricades, and any debris was been removed x <br /> COMMENTS <br /> Submit completed copy with other documentation In E-Maintenance. <br />