Laserfiche WebLink
i <br /> MONITORING AND REPORTING rROGRAM 00- - 6- <br /> CLASS II SURFACE IMPOUNDMENT <br /> THE BURLINGTON NORTHER AND SANTA FE RAILWAY CO . <br /> STOCKTON INTERMODAL FACILITY <br /> SAN JOAQUIN COUNTY <br /> Table 5 - LCRS Monitoring <br /> Parameters Units Frequency <br /> y. Field Parameter <br /> Flow Rate gallons/month Monthly <br /> Temperature °C Quarterly <br /> Specific Conductance umhos/cm Quarterly <br /> pH pH number Quarterly <br /> Monitoring Parameters <br /> mg/L Quarterly <br /> Total Dissolved Solids mg/L Quarterly <br /> TPH-diesel mg/L Quarterly <br /> TPH-oil & grease ug/L Quarterly <br /> Volatile Organic Compounds <br /> (EPA Method 8260, see Attachment C) mg/L Quarterly <br /> Chloride mg/L Quarterly <br /> Sulfate mg/L Quarterly <br /> Nitrate - Nitrogen mg/L Quarterly <br /> Dissolved Metals (Barium, Copper, Lead , <br /> & Zinc) <br /> All LCRSs shall be tested annually to demonstrate operation in conformance with waste discharge <br /> requirements . The results of these tests shall be reported to the Board and shall include comparison with <br /> earlier tests made under comparable conditions . <br /> I <br /> 6 . Surface Water Monitoring <br /> Surface water samples shall be sampled at upstream and downstream stations on Littlejohn Creek and <br /> Weber Slough quarterly when water is present. Surface water sample stations are SM- 1 , SM-2 , SM-3 <br /> and SM-4, shown on Attachment A. Surface water samples shall be analyzed for the following . <br />