My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2021 9:43:49 AM
Creation date
2/1/2019 1:52:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231074
PE
2351
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ OA U I Environmental Health Department <br /> CsU1T <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC#20632 4627 DA VINCI DR, STOCKTON February 06, 2019 <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> A copy of the financial responsibility documents were not available for inspection. A copy of these documents shall <br /> be accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 109 CCR 2637(a-d), 2712 Failed to test secondary containment, or failed to maintain test records for 36 months. <br /> A Secondary containment testing was performed on 10/10/2018 for the 87 and 91 tanks for one hour only . <br /> Another Secondary containment testing was last performed on 02/14/2019 for the 91 tank only and passed the <br /> 24hour testing as required. The 87 tank testing has not been completed and is past due. Secondary containment <br /> testing is required once every 36 months. Immediately schedule this test and provide 48 hours notification to the <br /> EHD. A copy of the test report must be submitted within 30 days of the test to EHD. <br /> This is a Class II violation. <br /> 124 CCR 2637.2(d&e), 2665(a&b)"Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days <br /> of inspection. <br /> The Overfill prevention testing was performed on 08/02/2018 and a test report was not submitted to EHD. A copy of <br /> the test report must be submitted within 30 days of the tests. Take all necessary precautions to ensure testing and <br /> submittal of test reports are performed in a timely manner and a copy submitted to EHD for review. <br /> This is a minor violation. <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 205 CCR 2712(1), 2634(e) Failure to submit a current UST Response Plan and have it available onsite. <br /> An approved copy of the response plan were not available for inspection. A copy of these plan shall be accessible on <br /> site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> FA0002541 PR0231074 SCO01 02/06/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 Of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.