My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LONGE
>
7679
>
2200 - Hazardous Waste Program
>
PR0537564
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 9:40:47 AM
Creation date
2/6/2019 9:36:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0537564
PE
2294
FACILITY_ID
FA0014430
STREET_NUMBER
7679
STREET_NAME
LONGE
STREET_TYPE
ST
City
STOCKTON
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
7679 LONGE ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
标签
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADVACARE 120 SANITIZER/SOUR <br /> Page:2/5 <br /> Section 5. Fire-fighting measures <br /> Flash point 96.1111 °C (Closed cup) <br /> Product does not support combustion. <br /> Hazardous thermal Decomposition products may include the following materials: <br /> decomposition products carbon dioxide <br /> carbon monoxide <br /> Fire-fighting media and Use an extinguishing agent suitable for the surrounding fire. <br /> instructions <br /> Use water spray to keep fire-exposed containers cool. Dike area of fire to prevent <br /> irunoff. <br /> Contact with combustible material may cause fire. This material increases the risk <br /> of fire and may aid combustion. In a fire or if heated, a pressure increase will <br /> occur and the container may burst. <br /> Special protective equipment Fire-fighters should wear appropriate protective equipment and self-contained <br /> for fire-fighters breathing apparatus (SCBA)with a full face-piece operated in positive pressure <br /> mode. <br /> I <br /> Section 6. Accidental release measures <br /> Personal Immediately contact emergency personnel. Stop leak if without risk. Eliminate all ignition <br /> precautions sources. Use suitable protective equipment. Keep unnecessary personnel away. Do not touch <br /> or walk through spilled material. <br /> Environmental Avoid dispersal of spilled material and runoff and contact with soil,waterways, drains and <br /> precautions sewers. Inform the relevant authorities if the product has caused environmental pollution <br /> (sewers, waterways, soil or air). <br /> Methods for If emergency personnel are unavailable, contain spilled material. For small spills, add <br /> cleaning up absorbent(soil may be used in the absence of other suitable materials), scoop up material and <br /> place in a sealable, liquid-proof container for disposal. For small spills, add absorbent(soil may <br /> be used in the absence of other suitable materials) and use a non-sparking or explosion-proof <br /> means to transfer material to a sealable, appropriate container for disposal. For large spills, <br /> dike spilled material or otherwise contain it to ensure runoff does not reach a waterway. Place <br /> spilled material in an appropriate container for disposal. <br /> Section 7. Handling and storage <br /> Handling Do not ingest. Do not get in eyes, on skin, or on clothing. Do not breathe vapor or spray. <br /> Avoid contact with combustible materials. Keep container closed. Keep only in the original <br /> container. Use only with adequate ventilation. Wash thoroughly after handling. Do not mix with <br /> bleach or other chlorinated products—will cause chlorine gas. <br /> Storage Keep out of reach of children. Keep container in a cool, well-ventilated area. Keep container <br /> tightly closed. Separate from reducing agents and combustible materials. <br /> Store between the following temperatures: -10 and 50°C <br /> Section 8. Exposure controls/personal protection <br /> Engineering measures : Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapor <br /> or mist, use process enclosures, local exhaust ventilation or other engineering controls <br /> to keep worker exposure to airborne contaminants below any recommended or statutory <br /> limits. Provide suitable facilities for quick drenching or flushing of the eyes and body in <br /> case of contact or splash hazard. <br /> Personal protection : <br /> Eyes Use chemical splash goggles. For continued or severe exposure wear a face shield over the <br /> goggles. <br /> Hands Use chemical-resistant, impervious gloves. <br /> Skin Wear suitable protective clothing. <br /> Respiratory Wear appropriate respirator when ventilation is inadequate and occupational exposure limits <br /> are exceeded. <br /> Name Exposure limits <br />
The URL can be used to link to this page
Your browser does not support the video tag.