Laserfiche WebLink
SOIL VAPOR EXTRACTION SYSTEM <br /> FIELD MONITORING DATA SHEETS <br /> Date U I Time of Arrival r �� <br /> Technician Time of Departures <br /> Site Engineer_ Scott Gable Was Site Engineer or substitute oo cted from field? <br /> Yes No <br /> PART A GENERAL INFORMATION <br /> Site Location 2905 Beniamin Holt Drive,Stockton.CA Station No.. Chevron#9-4275 Protect No 077.43508 550 <br /> Abatement Equip inab k Serial No <br /> SVE Blower Sutorbilt <br /> Max AMP Rating <br /> SPG Blower Gast - - —-- — MAX AMP Rating 10 <br /> Telemetry None <br /> Electrical Power 220 V 3 Phase Elect Meter Reading 15-3t"13171 <br /> Supplemental Fuel Supp Fuel Meter Reading <br /> No of WO barrels at site Full Empty <br /> PART B SVE SYSTEM DATA <br /> System up or down upon arrival '( ffa0a please complete PART E) <br /> Hourmeter Reading At time <br /> I) <br /> Flow Data Before Ad ustment Final Ideal Ran22 <br /> %Dilution air valve open <br /> %Recirculation valve open <br /> WO Content al <br /> Vacuum ® blower(In H2O) <br /> Gauge Ran <br /> AMPS drawn by blower motor AMPS <br /> Total System Flow(A P,in H2O) <br /> Pipe Size 0 " <br /> Well Field Air Flow(A P,in H2O) <br /> Pipe Size <br /> Dilution Air Flow(A P,`H2O) <br /> P[ILO Size 0 " <br /> li) <br /> FID Data WCAVOC/DF WCIWOC(DF Ideal Range <br /> System Influent my before dilution <br /> System Influent my after dilution <br /> Svstem Effluent my <br /> Field Instrument Used Last Calibrated <br />