My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0012556
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
3500 - Local Oversight Program
>
PR0544111
>
ARCHIVED REPORTS XR0012556
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 11:41:34 AM
Creation date
2/7/2019 11:15:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012556
RECORD_ID
PR0544111
PE
3528
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
02
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BATCH QC REPORT: Definitions and Terms � <br /> Accuracy The ability of a procedure to determine the"true"conceneation of an analyte <br /> Precision -flee reproducibility of a procedure demanstrated by the agreement between <br /> analyses performed on either duplicates of the same sample or a pas of <br /> duplicate spikes <br /> Batch A group of samples analyzed sequentially using the same calibration curve,, <br /> reagents,and instrument <br /> Laboratory Laboratory reagent water spiked with known compounds and subjected to the <br /> Control Standard same procedures as the sarrtples. The LCS thus indicates the accuracy of the <br /> (LCS) analytical method and,because it is prepared from a different source than the <br /> standard used to calibrate the instrument,it also serves to double-check the <br /> calibration <br /> Matrix QC Quality control tests performed on actual client samples. For most inorganic <br /> analyses,the laboratory uses a pair of duplicate samples and a spiked sample. <br /> For most organic analyses,the laboratory w�cs a pair of spiked samples <br /> (duplicate spikes) <br /> LC Result Laboratory result of an LCS analysis <br /> LT Result Expected result,or true value,of the LCS analysis <br /> f R1,R2 Result: Result of the analysis of replicate aliquots of a sample,with R1 indicating the <br /> first analysis of the sample and R2 its corresponding duplicate;used to <br /> dcterrrin--precision <br /> S 1,S2 Result Result of the analysis of replicate spiked aliquots,with S 1 indicating one <br /> spike of the sample and S2 the second spike;used to determine precision and <br /> accuracy <br /> R Bar Result The average of replicate analysis results <br /> S Bar Result: The average of spike analysis results <br /> True value The theoretical,or expected,result of a spik:sample analysis <br /> I <br /> Percent The percentage of analyte recovered <br /> Recovery For LCS,the percent recovery calculation is: LC+LTx 100 <br /> For spike mcoveri_s,the percent recovery calculadion is: <br /> (S Bar-SampleConcentratigni x 100 <br /> Spike Amount <br /> Relative Percent Calculated using one of the following: <br /> Difference(RPD) (R 1 -R2)x 100 (51 2}_x 109 <br /> (RI +R2) 2 (Sl +S2)+2 <br /> Blank Result The result of the analysis of a method blank,which is reagent water that is <br /> analysed using the same reagents,instruments and procedures as the samples <br /> in a batch;used to determine laboratory contamination <br /> Reporting Detec- BCA-assigned limit based on---but not the same as—method detection limits <br /> tion Limit(RDL) (NIDI determined using EPA guidelines <br /> 13 C Analytical <br />
The URL can be used to link to this page
Your browser does not support the video tag.