Laserfiche WebLink
ATTACHMENT A <br /> REMEDIAL SYSTEM PERFORMANCE EVALUATION <br /> Soil vapor extraction (SVE) and air sparging were initiated on January 1, 1995 and May 5, 1995, respectively <br /> A groundwater extraction system operated at the site between 1991 and 1996 A brief description and <br /> performance evaluation of the remedial system between September 27, 2000 and December 14, 2000 is <br /> presented below Field data, analytical reports, and chain-of-custody documentations are presented in <br /> Attachment A-A <br /> SVE System <br /> The SVE system is comprised of 14 SVE wells (V-1 through V-13, and E-6) and an Airex Katox 100 catalytic <br /> oxidizer The SVE system is permitted by the San Joaquin County Unified Air Pollution Control District <br /> (SJVUAPCD)Permit to Operate Number N-3601-1-0,which expires on January 1,2001 <br /> The SVE system was re-started on March 15, 2000 after being off due to high groundwater elevations making <br /> operation of the SVE system not feasible The SVE system was approximately 100 percent operational during <br /> the month of October, at which time the system was shut off due to low influent concentrations SVE system <br /> influent data is presented in Tables A-1 and A-2, and a plot of SVE system influent soil vapor TPHg, benzene, <br /> and MtBE concentrations versus time is shown as Figure A-2 A plot of cummulative mass removal data is <br /> presented in Figure A-1 During the fourth quarter of 2000, influent concentrations of TPHg, benzene and <br /> MWE were non detect Therefore,during the fourth quarter,the SVE system removed an undetermined mass of <br /> these hydrocarbons from the soil beneath the site SVE system performance data is included in Table A-1 SVE <br /> emission data is presented in Table A-3,and SVE operational data, including well open/closed status,flow rate, <br /> and applied vacuum data,are presented in Table A-4 <br /> Air Sparging System <br /> The air spargmg system is comprised of 9 air spargmg wells (S-1 through S-9) and a MD Pneumatics Model <br /> 3202 7 5-horsepower blower During the fourth quarter, the air spargmg system was fully operational Air <br /> spargmg system operational data, including well open/closed status, flow rate, and applied pressure data are <br /> presented in Table A-5 Monitoring well dissolved oxygen data is included with groundwater elevation and <br /> analytical data in Table 1 and Table A-6 Treatment system field data sheets are included as Attachment A-A <br />