Laserfiche WebLink
Lancaster Laboratories <br /> Explanation of Symbols and Abbreviations <br /> The following defines common symbols and abbreviations used in reporting technical data • <br /> N D none detected BMQL Below Minimum Quantitation Level <br /> TNTC Too Numerous To Count MPN Most Probable Number <br /> IU International Units CP Units cobalt-chloroplatinate units <br /> umhos/cm micromhoslcm NTU nephelometric turbidity units <br /> C degrees Celsius F degrees Fahrenheit <br /> Cal (diet) calories lb pound(s) <br /> meq milliequivalents kg kilogram(s) <br /> g gram(s) mg milligram(s) <br /> ug microgram(s) - I liter(s) <br /> M1 milliliter(s) ul - microliter(s) <br /> m3 cubic meter(s) fib >5 umlml fibers greater than 5 microns in length per ml <br /> less than -The number following the sign is the limit of guantitation, the smallest amount of analyte which can <br /> be reliably determined using this specific test <br /> > greater than <br /> PPM parts per million-One ppm is equivalent to one milligram per kilogram (mglkg), or one gram per million grams <br /> _For aqueous liquids,-ppm is usually taken to be equivalent to milligrams per liter (mg/1), because one liter of <br /> water has a weight very close to a kildgrarn For gases or vapors, one-ppm is equivalent to one microliter of- - -- <br /> gasRper titer of_gas <br />-- - ---- -ppb -- parts per billion-- <br /> Dry weight Results printed under this heading have been adjusted for moisture content This increases theanalyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture <br /> U S EPA data qualifiers <br /> Organic Qualifiers Inorganic Qualifiers <br /> A TIC is a possible aldol-condensation product B Value is <CRDL, but yIDL <br /> B Analyte was also detected in the blank E Estimated due to interference <br /> C Pesticide result confirmed by GCIMS M Duplicate infection precision not met <br /> D Compound quatitated on a diluted sample N Spike amount not within control limits <br /> E Concentration exceeds the calibration range of S Method of standard additions (MSA) used <br /> the instrument for calculation <br /> J Estimated value U Compound was not detected <br /> N Presumptive evidence of a compound (TICs only) W Post digestion spike out of control limits <br /> P Concentration difference between primary and + DuCorrelationlcoefficient within <br /> r MSA ncontrol <br /> glimits <br /> i its <br /> confirmation columns >25% <br /> U Compound was not detected <br /> X,Y,Z Defined in case narrative <br /> Analytical test results for methods listed on the laboratories' accreditation scope meet all requirements of NELAC unless <br /> otherwise noted under the individual analysis <br /> Tests results relate only to the sample tested Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample Unless the sample analyzed is truly representative of the bulk of material involved, the <br /> test results will be meaningless If you have questions regarding the proper techniques of collecting samples, please contact <br /> us We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br /> staff This report shall not be reproduced except in full, without the written approval of the laboratory <br /> WARRANTY AND LIMITS OF LIABILITY— In accepting analytical work, we warrant the accuracy of test results for the sample as submitted <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LiEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br /> IMPLIED WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LO <br /> OF PROFIT OR GOODWILL REGARDLESS OF (A)THE NEGLIGENCE (EITHER SOLE OR CONCURRENT)OF LANCASTER <br /> LABORATORIES AND (B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH <br /> DAMAGES We accept no legal responsibility for the purposes for which the client uses the test results No purchase order or other order <br /> for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of <br /> Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client <br />