HUNTER ENVIRONMENTAL SERVICES, INC. <br />18350 MT. LANGLEY STREET, SUITE 101 <br />FOUNTAIN VALLEY, CA 92708 <br />800-247-9014 800-241-2186 <br />CUSTOMER: ARCO <br />ADDRESS: 25775 S. PATTERSON PASS <br />TRACEY, CA <br />TEST RESULTS SUMMARY <br />FINAL TEST RESULTS <br />TEST DATE: 3/20/88 <br />LOCATION/IDENTIFICATION NO.: 6100 <br />------------------------------------------------------- <br />SYSTEM <br />TANK <br />SIZE <br />WATER <br />NO. <br />----------------------------------- <br />PRODUCT------- <br />-------GALLDNS --DIA/MATL <br />CONCLUSION ------RECOMMENDATIONS- <br />INCHES <br />1 <br />S/U <br />6000 <br />95/ST <br />0 <br />2 <br />U/L #1 <br />6000 <br />95/ST <br />0 <br />50 <br />UiL #2 <br />6000 <br />95/ST <br />0 <br />3 <br />REG #1 <br />6000 <br />95/ST <br />0 <br />---Y/N <br />REG #2 <br />6000 <br />95/ST <br />0 <br />FINAL TEST RESULTS <br />TEST DATE: 3/20/88 <br />LOCATION/IDENTIFICATION NO.: 6100 <br />------------------------------------------------------- <br />LEAK <br />-LOKATOR -RESULTS <br />LEVEL <br />ALR <br />PRODUCT PRODUCT CONCLUSION <br />INCHES <br />GPH <br />CONCLUSION ------RECOMMENDATIONS- <br />150 <br />150 <br />-.002 <br />TIGHT <br />160 <br />+,010 <br />TIGHT <br />150 <br />+,038 <br />TIGHT <br />PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br />SYSTEM <br />TYPE OF -PUMP--- <br />-------------- <br />POUNDS <br />POUNDS <br />MINUTES <br />PRODUCT PRODUCT CONCLUSION <br />NO. PRODUCT <br />---------------------------------------------------------------------------------------------------------------- <br />REMOTE SUCTION <br />APPLIED <br />HELD <br />HELD <br />LOSS CC's LOSS 6PH /RESULT <br />I S/U <br />UNKNOWN <br />5U <br />44 <br />10 <br />PASS <br />2 U/L <br />RED JACKET <br />50 <br />50 <br />10 <br />PASS <br />3 REG <br />RED JACKET <br />50 <br />50 <br />10 <br />PASS <br />NOTE: On suction systems, NEVER out more than 15 psi on any pump system. <br />DETAIL OF TEST RESULTS <br />*LEVEL - Inches from Tank Bottom to Test Level <br />ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br />CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness CERTIFIED <br />CERTIFICATION <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br />LOKATOR according to all standard operating procedures. Those indicated as tiqht at full system meet the criterion <br />established by the National Fire Protection Association Pamphlet 329 for Precision Testinq. <br />Tests Conducted and Certified By: Test Van No. 7 <br />Team Manager: P. WHEELER <br />Tank Testing Specialist: S. ANDERSON <br />TEST <br />TIME <br />--------------- <br />LEAK <br />----------- <br />RATE --- <br />TEMPERATURE <br />ABSOLUTE <br />CHECK <br />SYSTEM <br />TEST LEVEL <br />CLOCK <br />DURATION <br />COMPENSATION <br />LEAK <br />RATE <br />TEST <br />NO. <br />------------------------------------------------------------------------------------------- <br />PRODUCT <br />NO. (IN.) <br />-STATE--(HR-MIN)--CC/DIV--CC/MIN <br />CC/MIN <br />DELTA of -------- <br />CC/MIN <br />GPH <br />---Y/N <br />1 <br />S/U <br />1 150 <br />1:15 <br />:60 <br />-8.000 <br />-8.869 <br />-,035 -8.743 <br />-.126 <br />-.002 <br />N <br />2 <br />U/L #1 <br />1 160 <br />9:45 <br />:60 <br />+1.923 <br />+5,920 <br />+,003 +.749 <br />+.672 <br />+.010 <br />N <br />3 <br />U/L #2 <br />1 160 <br />9:45 <br />:60 <br />+1.923 <br />+5.920 <br />+.018 +4,496 <br />+.672 <br />+.010 <br />N <br />4 <br />REG #1 <br />1 150 <br />12:05 <br />:60 <br />+4.196 <br />+19.426 <br />+,032 +7.993 <br />+2.439 <br />+,038 <br />N <br />5 <br />REG #2 <br />1 150 <br />12:05 <br />:60 <br />+4,196 <br />+19.426 <br />+,036 +8.993 <br />+2.439 <br />+,038 <br />N <br />*LEVEL - Inches from Tank Bottom to Test Level <br />ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br />CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness CERTIFIED <br />CERTIFICATION <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br />LOKATOR according to all standard operating procedures. Those indicated as tiqht at full system meet the criterion <br />established by the National Fire Protection Association Pamphlet 329 for Precision Testinq. <br />Tests Conducted and Certified By: Test Van No. 7 <br />Team Manager: P. WHEELER <br />Tank Testing Specialist: S. ANDERSON <br />