Laserfiche WebLink
Client Name: Groundwater Technologies Date: 09/15/1994 <br /> Client Acct: 417 FLAP Cert: 1386 <br /> \J ® NET Job No: 94.03985 Page: 7 <br /> Ref: ARCO 6080, Lathrop, GTI-GC-A94-5 <br /> I <br /> 1 <br /> CONTENUING CALIBRATION VERIFICATION STANDARD REPORT <br /> i <br /> CCv Ccv <br /> CCv Standard Standard �! <br /> Standard Amount Amount Date i} Analyst <br /> Parameter V RecoveryFound Expected_ Units_____ Analyzed (ii Initials ! <br /> TPH (Gas/BTXE,Liquid) <br /> as Gasoline 99.0 0.99 1.00 mg/L 09/11/1994:! aal <br /> Benzene 95.4 4.77 5.00 ug/L 09/11/1994: aal <br /> Toluene 92.8 4.64 5.00 ug/L 09/11/1994 aal <br /> Ethylbenzene 92.4 4.62 5.00 ug/L 09/11/1994, aal <br /> Xylenes (Total) 94.7 " 14.2 15.0 ug/L 09/11/1994 aal <br /> Bromofluorobenzene (SURR) 120.0 120 100 t Rec. 09/11/X994 . aal <br /> SFr+ <br /> sj <br /> NOM Results apply only to the samples analyzed. Reproduction of this report is permitted Only in its entirety. <br />