Laserfiche WebLink
No Further Action Required Request Report <br /> Tracy Byron Road-Tracy,California December 1,201 I <br /> 5. Provide scaled site maps of the area impacted showing locations of former and existing <br /> tank systems, excavation and sample locations, boring and monitoring well locations, <br /> rgroundwater elevation contours,subsurface utilities, buildings, streets, and any nearby <br /> surface waters. <br /> ' The locations of current structures,former pipelines,and sampling locations are shown on <br /> Figure 2. The affected areas at the Site encompass approximately 27 acres. Areas 1,2, and <br /> 3 measure approximately 200 feet by 1,400 feet, 375 feet by 2,000 feet, and 200 feet by 650 feet, <br /> respectively. The extent of affected soil and groundwater is indicated on Figure 3. No <br /> monitoring wells were installed at the Site,and therefore, no groundwater elevation contours <br /> were generated. <br /> 6. Provide boring logs and cross-sections to show site lithology. <br /> Boring logs from the SAIC environmental investigations are provided as components of <br /> Appendices B.l through B.3. No cross sections have been generated. <br /> 7. Report the volume of excavated soil disposed off-site, or remaining on site. <br /> Soil excavation has not been conducted with the exception of minor amounts of soil removed <br /> during investigation activities. No investigation-derived waste remains on the Site. <br /> 8. Describe the fate of any remaining monitoring and remediation wells (destroyed, <br /> ownership transferred, or to remain in use). <br /> No monitoring or remediation wells were installed at the Site. <br /> 9. Provide tabulated results of all groundwater elevations and depths to water. <br /> ' During the SAIC investigations, static depths to water at the Site were reported between 10 and <br /> 25 feet bgs. Surveying the surface elevations of soil borings was not a component of any <br /> previous investigation;therefore,groundwater elevations have not been calculated. <br /> 10. Provide tabulated results of all sample analyses, including the sampling method and <br /> detection limits. Analytical results must include TPH and BTEX constituents, lead, <br /> MTBE,EtBE, TBA,ETRE,DIPS, TAME,ethanol, methanol, ethylene dibromide, 1,2- <br /> dichloroethane, and other constituents as indicated in Table#2 above. Provide any WET <br /> or TCLP results. <br /> Soil and groundwater analytical results for the COPCs(TPHc, BTEX, and PAHs)are included as <br /> Appendix C. Lead,MTBE,EtBE,TBA,ETBE,DIPE,TAME, ethanol, methanol,ethylene <br /> dibromide, and 1,2-dichloroethane are not COPCs,and were therefore not analyzed. WET and <br /> TCLP tests have not been performed on soil samples. <br /> 11. Discuss concentration and mass changes over time, and current concentrations of <br /> contaminants remaining in groundwater at the site. <br /> SAIC identified three areas of affected soil and groundwater covering a total of 27 acres. <br /> Significant changes of plume size or COPC concentrations, if measurable, would not be expected <br /> on a quarterly, semi-annual,or even an annual basis. Thus, a monitoring-well network was not <br /> installed to track plume stability or concentration trends. Current concentrations of the COPCs <br /> at the Site are likely to be less than levels recorded during previous investigations due to natural <br /> attenuation of the residual hydrocarbons. The concentrations of COPCs do not pose a threat to <br /> 7 SAIL <br /> 1 <br />