Laserfiche WebLink
TABLE 1 <br /> Soil Chemical Analytical Data <br /> Tracy Byron Road <br /> Tracy,California <br /> Concentrations reported in milligrams per kilogram(mg/kg) <br /> Sample <br /> Soil Boring Depth Date Ethyl- Total <br /> (SB)ID (feet bgs) Collected TPHc Benzene Toluene benzene Xylenes <br /> SB-36-8 8 10/30/03 29600 <0.0513 0.1 0.3 3.2 <br /> SB-36-12 12 10/30/03 19900 <0.055 0.1 0.3 <1.55 <br /> SB-36-32 32 10/30/03 <4.0 <0.005 <0.005 <0.005 <0.02 <br /> Notes: <br /> bgs=Below ground surface <br /> TPHc=Total petroleum hydrocarbons quantified as crude oil(C1O through C36) <br /> <=Less than laboratory reporting limits <br /> 1. TPH was detected in the method blank at a concentration of 6.4 mg/kg. Since TPH was not detected <br /> in the sample,the results are reported. <br /> 2. TPH was detected in the method blank associated with this sample. Since the TPH concentration in the sample is <br /> more than 5 times the blank value,the data is reported. <br /> 3. Due to the presence of an interferent near its retention time,the normal reporting limit was not attained for <br /> benzene. The concentration of the compound cannot be determined due to the presence of this interferent. <br /> 4. TPH was detected in the method blank at a concentration of 6.4 mg/kg. The blank value was not subtracted from <br /> the analytical result. <br /> 5. Due to the nature of the sample matrix,normal reporting limits were not attained. <br /> 6. TPH was not detected in the method blank associated with this sample. No TPH was detected in the method <br /> blank from a second extraction. Since the hold time had expired prior to the reextraction,all results are reported <br /> from the original extract. Similar results were obtained in both extracts. <br /> 7. Due to the nature of the sample matrix,a reduced aliquot was used for analysis. The reporting limits were raised <br /> accordingly. <br /> 8. Due to insufficient sample size,Lancaster Laboratory was unable to report their usual reporting limits. The <br /> values reported represent the lowest reporting limits obtainable. <br /> 9. Due to the presence of an interferent near its retention time,the normal reporting limit was not attained for <br /> total xylenes. The presence or concentration of this compound cannot be determined due to the presence of this <br /> interferent. <br /> 10. Due to excessive foaming of the sample it was diluted,therefore normal reporting limits were not attained. <br /> 11. The sample was received at the laboratory outside the extraction hold time. <br /> 12. Due to the dilution of the sample made necessary by the high level of non-target compounds,normal reporting <br /> limits were not attained. <br /> 13. The reporting limits were raised because sample dilution was necessary to bring target compounds into the <br /> calibration range of the system. <br /> Page 4 of 4 <br />