Laserfiche WebLink
TABLE 2 <br /> Soil Chemical Analytical Data(PAHs) <br /> Tracy Byron Road <br /> Tracy, California <br /> Concentrations reported in milligrams per kilogram(mg/kg) <br /> Dibenzo <br /> Soil Sample Benzo(b)- Benzo- Benzo(k) (a,h) Indeno <br /> Boring Depth Date Acenaph- Acenaph- Anthra- Benzo(a)- Benzo(a)- fluor- (g,h,i) fluoran- anthra- Fluoran- (1,2,3-cd) Naph- Phenan- <br /> (SB)ID (feet bgs) Collected thene thylene Gene anthracene pyrene anthene perylene thene Chrysene cene thene Fluorene pyrene thalene threne Pyrene <br /> SB-35-74 7 10/30/03 1.1 <0.017 1.4 0.30 0.17 0.14 0.099 0.064 1.1 0.050 0.47 0.96 0.059 2.5 3.8 1.5 <br /> SB-35-24 24 10/30/03 <0.0003 <0.0003 <0.0003 <0.0003 <0.0003 <0.0003 <0.0003 <0.0003 <0.0003 <0.0003 <0.0007 <0.0003 <0.0003 <0.001 0.0005 <0.0003 <br /> SB-36-84 8 10/30/03 0.15 <0.003 0.15 0.021 0.007 0.017 0.008 0.020 0.058 <0.003 0.040 0.52 <0.003 0.90 0.91 0.093 <br /> SB-36-124 12 10/30/03 0.15 0.043 0.14 0.017 0.008 0.018 0.008 0.020 0.063 <0.003 0.040 0.54 <0.003 0.94 0.90 0.095 <br /> SB-36-32 32 10/30/03 0.0003 <0.0003 0.0007 <0.0003 <0.0003 <0.0003 <0.0003 <0.0003 0.0003 <0.0003 <0.0007 0.002 <0.0003 <0.001 0.005 0.0006 <br /> Notes: <br /> PAHs=Polynuclear aromatic hydrocarbons <br /> bgs=Below ground surface <br /> <=Less than laboratory reporting limits <br /> 1. The surrogate data is outside the QC limits due to unresolvable matrix problems evident in the sample extract. <br /> 2. The recoveries of several compounds were outside of QC limits in the LCS. This sample was re-extracted outside of the method holding time,and acceptable QC and comparable data was not observed. The data reported here <br /> is from initial extraction of the sample. <br /> 3. The sample was received at the laboratory outside the extraction hold time. <br /> 4. Due to the sample matrix an initial dilution was necessary to perform the analysis. Therefore,the reporting limits for the GUMS semivolatile compounds were raised. <br /> 5. Phenanthrene was detected in the method blank at a concentration of 0.0003 mg/L. The blank value was not subtracted from the analytical result. This sample was re-extracted outside holding time and comparable results <br /> were detected. Phenanthrene was not detected in the method blank associated with the re-extract. <br /> 6. Phenanthrene was detected in the method blank at a concentration of 0.0003 mg/L. The blank value was not subtracted from the analytical result. <br /> 7. Phenanthrene was detected in the method blank at a concentration of 0.0003 mg/L. The blank value was not subtracted from the analytical result. This sample was re-extracted outside holding time and phenanthrene <br /> was not detected in the sample or the associated method blank. <br /> Page 4 of 4 <br />