Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike,PO Box 12425,Lancaster,PA 17605-2425-717-656-2300 Fax:717-656-2681•www.larcasterIabs.com <br /> Page 1 of 2 <br /> Lancaster Laboratories Sample No. WW 5003022 <br /> QA-R-070312 Grab Water <br /> Tracy Byron Road SAIC <br /> Byron Road-Tracy, CA N/A QA <br /> Collected:03/12/2007 12:50 by AS Account Number: 11413 <br /> Submitted: 03/13/2007 09:20 Chevron Environmental Mgt. Co. <br /> Reported: 03/26/2007 at 15:40 P.O. Box 6012, Room K-2066 <br /> Discard: 04/26/2007 San Ramon CA 94583 <br /> BYRRB SDG#: OVS58-03RB <br /> As Received <br /> CAT As Received Program Dilution <br /> No. Analysis Name CAS Number Result RL Units Factor <br /> 06912 TPH-DRO (C10-C25) Water n.a. 71. 50. ug/l 1 <br /> The observed sample pattern is not typical of #2 fuel/diesel. The reported <br /> result is due to individual peaks eluting in the DRO range. <br /> 06913 TPH-DRO(C10-C25)Water w/ SiGel n.a. N.D. 50. ug/l 1 <br /> 06570 PAHs in Water by LVI GC/MS <br /> 06576 Naphthalene 91-20-3 0.79 0.010 ug/l 2 <br /> 06579 Acenaphthylene 208-96-8 0.015 0.010 ug/l 2 <br /> 06580 Acenaphthene 83-32-9 N.D. 0.010 ug/l 2 <br /> 06581 Fluorene 86-73-7 0.12 0.010 ug/1 2 <br /> 06582 Phenanthrene 85-01-8 0.13 0.010 ug/l 2 <br /> 06583 Anthracene 120-12-7 0.010 0.010 ug/l 2 <br /> 06584 Fluoranthene 206-44-0 0.013 0.010 ug/l 2 <br /> 06585 Pyrene 129-00-0 0.010 0.010 ug/l 2 <br /> 06586 Benzo(a)anthracene 56-55-3 N.D. 0.010 ug/l 2 <br /> 06587 Chrysene 218-01-9 0.034 0.010 ug/1 2 <br /> 06588 Benzo(b)fluoranthene 205-99-2 N.D. 0.010 ug/l 2 <br /> 06589 Benzo(k)fluoranthene 207-08-9 N.D. 0.010 ug/l 2 <br /> 06590 Benzo(a)pyrene 50-32-8 N.D. # 0.0059 ug/l 2 <br /> 06591 Indeno(1,2,3-cd)pyrene 193-39-5 N.D. 0.010 ug/l 2 <br /> 06592 Dibenz(a,h)anthracene 53-70-3 N.D. # 0.0059 ug/l 2 <br /> 06593 Benzo(g,h,i)perylene 191-24-2 N.D. 0.010 ug/l 2 <br /> Acenaphthylene was detected in the method blank at a concentration of .0062 <br /> ug/1. The blank value was not subtracted from the analytical result. <br /> Due to the sample matrix an initial dilution was necessary to perform the <br /> analysis. Therefore, the reporting limits for the GC/MS semivolatile <br /> compounds were raised. <br /> 02898 EPA SW846/8260 (water-25ml) #1 <br /> 02942 Benzene 71-43-2 N.D. 0.1 ug/l 1 <br /> 02965 Toluene 108-88-3 N.D. 1.0 ug/l 1 <br /> 02976 Ethylbenzene 100-41-4 N.D. 1.0 ug/l 1 <br /> 02900 EPA SW846/8260 (water-25ml) #3 <br /> 05308 Xylene (Total) 1330-20-7 N.D. 1.0 ug/l 1 <br /> #=Laboratory MethodDetection Limit exceeded target detection limit <br /> N.D.=Not detected at or above the Reporting Limit <br />